www.BISSELL.com.au
10
Clearing a Clog
Remove the hose
from the back of the
vacuum by twisting
it to the left. Remove
any debris that may
have gotten clogged.
Check the foot hose on
the back of your vacuum
down towards the bottom.
If necessary, remove the
screw from the foot hose
and check for clogs.
Check the air passageway on
the bottom of your vacuum.
Remove the bottom cover and
the brush. Remove any debris.
1
2
3
Replace the Brush & Belt
Unplug vacuum, turn
over and unscrew 6
Philips head screws to
remove bottom cover.
Lift roller straight out.
Inspect belt, replace if
it appears damaged.
If the belt is not broken, remove
roller from inside of looped
belt. Inspect brush roll by
placing it on its end and spin.
The brush roll should spin freely,
multiple times by one flick. If it
doesn’t, replace brush roll.
Replace the brush roll and belt
by looping the belt over the
motor shaft and the brush roll.
Line up the end caps and pull
the brush forward into place.
This will stretch the belt.
Once the brush roll is installed,
place the bottom cover back on
and replace the screws.
End Cap
Belt
1
2
3
4
5