→ Check the cable for connection and
the breakage of the wire
・Magnet contactor thermal relay activated
→ Identify the cause and reset
・Primary-side circuit breaker tripped
→ Reset primary-side circuit breaker
(Less than 0.5MPa)
・Motor runs in the wrong direction
→ Replace R, and T phases of cable
at lower portion of scissors
・Lowering Stop Hook is engaged with rack
→ Raise the lift once and then lower
at lower portion of scissors
・Lack of oil
→ Fill the oil
→ Normal. Vehicle exceeding the lift
capacity can not be lifted up
at 10 minutes after lift was stopped, it is
normal
・Supporter height would be synchronized at
max height
unbalance happens often
・Lack of oil
→ Fill the oil
・Lack of lubrication at scissors bearing
→ Lubricate
→ Greasing to sliding portion
・Wear of Link Rollers
→ Replace Rollers
-21 -
・Lack of oil inside Synchro Cylinder
→ Fill the oil
→ Adjust the air pressure to specified
→ Remove foreign articles
・Overload
→ Remove foreign articles
・Contact defect of Push Button Switch
→ Replace Push Button Switch
・Foreign Articles are obstructing the roller
・Foreign Articles are obstructing the roller
・Lack of lubrication at shoe sliding portion
→ Contact lift supplier if the height
・Pressure of air supplied to lift is too low
・Breakage of motor cable・Burnt Motor
→ Identify the cause and replace motor
・Power cable improperly connected or broken
If natural lowering is less than 1mm/5 minutes
→ If natural lowering is more than
1mm/5 minutes, contact lift supplier.
Before performing any electrical work, be sure to turn off the power supply.