ー 6 ー
Make sure to drain Air Filter Regulator before starting operation.
If water drop goes inside of air circuit, lift may not work properly, and may
result in personal injury or property damaging accident.
Warning
Supply dry air. If not, lift would be broken.
Caution
Make sure to check if the pressure at Gauge is 0.5MPa before starting
operation.
If the pressure is lower than 0.5MPa, lift may not work properly.
If the pressure is more than 0.5MPa, it may damage Air Switching Valve.
Caution
( Air Filter Regulator )
Air Filter Regulator adjusts the supplied air pressure
(0.7-1.0MPa) down to appropriate pressure (0.5MPa).
It also filters the water in the air.
Pressure Gage indicates air pressure adjusted by the Regulator.
〈 Operation Method 〉
◎ Check if the air pressure supplied to the
Regulator is more than 0.7MPa.
◎ Loosen Top Screw first. Then watch Guage and
adjust air pressure to 0.7 MPa by turning
Adjusting Knob.
turn right: pressure UP
turn left: pressure DOWN
◎ Fix Top Screw after adjusting the air pressure.
〈 How to drain 〉
Push up Drain valve. Water comes out during
the valve is pushed up.