2.1 Example of a sliding gate operator installation

Before using the machine, check power supply, grounding, voltage, etc. 
Check whether it is connected according to the demand of wiring diagram. 
The gate should be pulled easily and smoothly manually when the worm gears are 
released. 
The worm gears will be coupled before power on

.

The product must be installed by professional person.
Means for disconnection must be incorporated in the fixed wiring in accordance 
with the wiring rules.
The diameter of wire on the wall not less than 1mm²,the diameter of wire that con-
nect to appliance not less than 0.5mm²
The external diameter of power line not more than 14mm, the power line should 
have polychloroprene sheathed cable and at least normal polychloroprene 
sheathed cable.

2.  Installation

BS-PY82L
Alarm Lamp
Gate wheel
Photocell (Optional)

Rack
Transmitter
Photocell (Optional)

1

2

3

4

5

6

7+8

2

3

4

5

6

7

8

1

Содержание BS-PY82L-120DC

Страница 1: ...PY L DC Brushless Sliding Gate Opener INSTALLATION MANUAL USER GUIDE ...

Страница 2: ...ges etc may be used to prevent any potential risk in dangerous areas where the moving mechanism is located such as crushing dragging or shearing BS accepts no responsibility regarding safety and correct operation of the machine should components made by manufacturers other than we be used in the system Do not make any alterations to the components of the automatic machine opener and accessory The ...

Страница 3: ...d out if the appliance is automatically controlled The temperature range marked on the drive should be suitable for the location The electrical cord plug must plug in indoor outlet or waterproof cover outlet Ensure that entrapment between the driven part and the surrounding fixed parts due to the opening movement of the driven part is avoided After installation ensure that the mechanism is properl...

Страница 4: ... control board Terminals for Push button Photocell Alarm lamp Auto closing is available time delay is adjustable 1 Gearbox 2 Release Clutch 3 DC Motor 4 Electromagnetic Brake 5 Transformer 6 LED Light 7 Motor Cover 8 Gear Reducer 9 Control Board 10 Limit Switch 11 Output Pinion ...

Страница 5: ...30m 1 4 Feature 1 3 Technical Specifications 1 The eletromagnetic brake could lock the operator when power off 2 In case of power failure the gate can be opened and closed manually after release clutch 3 Soft start function 4 Reverse or stop when meet obstacle the two functions is optional 5 Soft stop or limit brake function is optional 6 Auto close delay function 7 Applicable to access control sy...

Страница 6: ...nstalled by professional person Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules The diameter of wire on the wall not less than 1mm the diameter of wire that con nect to appliance not less than 0 5mm The external diameter of power line not more than 14mm the power line should have polychloroprene sheathed cable and at least normal polychloroprene...

Страница 7: ...he baseplate Key Ensure baseplate on level position M8 Bolt Door opener Base Plate 2 2 installation and adjustment Bolt Output pinion of sliding gate opener Rack 1 7 3 m m 300mm 20mm B A C Power 300mm Baseplate Baseplate Wheel Slide way Gate Rack Expansion Bolt Concrete base ...

Страница 8: ... magnet on the rack the gear box of the operator must be released asper Fig7 use the key turn clockwise to release the gear release key unlock lock release cover 2 3 Power Connection Rack Gate Output Pinion Wheel Slide way Gasket Base plate Fig7 Concrete base ...

Страница 9: ...play 1 2 3 4 ON DP Dip switch Function Opening Closing Stop Reach open limit Reach close limit Set transmitter LED Set transmitter button DIP Switch Loop Close Stop Open Photoccll Close limit Open limit Electromagnetic Brake Motor wires Transformer 24V input LED Alarm Lamp Yellow Green Blue 10A Fuse Airwave switch Receiue Trans mitter Y G B 3 Control board Display ...

Страница 10: ...it set interface Px setting X 1 9 No Parameter Description Protect time for motor running unit second motor will stop when over time Motor speed Lever 1 to 5 Min 1 Max 5 Reduce speed distance 0 15 Sensitivity of reverse when obstacle 0 50 Limit set 0 Normal Open 1 Normal Close Auto close delay time 0 99 0 no Auto close Sofe stop reduce speed 1 5 1 Fastest 5 Slowest Sofe stop 0 no Soft stop 1 valid...

Страница 11: ...ll 1 Change limit magnet 2 Rectify limit magnet 3 Adjust the magnet pole 1 Check power supply 2 Change fuse 3 Change capacitor 4 Check if any barrier on track 5 Restart after 20 minutes 4 2 2 Erase travel Gate opener must relearn travel and limit position method is power on operate the opener open and close one time don t push stop or don t active photocell if display YS means learning successfull...

Страница 12: ...t Check motor wires connectors Move away the obstacle or adjust the reverse level Remove the object that block the photocell Remove the obstacle orcheek the motor Restart or change the control board Check the hull connectors or change the motor Error Codes 6 Maintain 1 Frequently cheek the wires connectors especially the outter connetors 2 Check the GND make swire connection are as required 3 Chec...