WARNING TO THE INSTEALLER AND USER

CAUTION! For personal safety it is important to follow all the instructions 
carefully.Incorrect installation or misuse of the product may cause serious harm to        
people.
Keep the instructions in a safe place for future reference.
This product was designed and manufactured strictly for the use indicated in this 
document. Any other usage not expressly indicated in this Document,may damage
the product  and /or be a source of danger.
BS accepts no responsibility due to improper use of the automatic machine (open-
er) or use other than that intended.
Do not install the machine in an area subject to explosion hazard.Inflammable 
gasses or fumes are a serious safety hazard.
BS will not accept responsibility if the rules of good workmanship are disregarded 
in installig the closing elements to be motorised, if any deformation occurs during 
use of the said elements.
Before carrying out any work on the system, turn off the electricity supply.
The safety devices(e.g.photocells,sensitive edges,etc … ) may be used to prevent 
any potential risk in dangerous areas where the moving mechanism is located, 
such as crushing, dragging, or shearing.
BS accepts no responsibility regarding safety and correct operation of the 
machine, should components  made by manufacturers other than we be used in 
the system.
Do not make any alterations to the components of the automatic machine (opener 
and accessory ).
The installer must supply full information regarding operation manual of the 
system in the event of any emergency and provide the system user with the 
“INSTRUCTION”included with the product.
Do not allow children of other people to stand nera any  moving part of the opener 
or door construction while in operation.
Keep transmitters away from children to prevent the machine from being activated 
accidentally.
The user must refrain from attempting to repair or adjust the system personally 
and should only contact professional personnel.
Frequently examine the installation, in particular check cables, springs and 
mountings for signs of wear, damage or imbalance, Do not use if repair or 
adjustment is needed since a fault in installation or an incorrectly balanced door 
may cause injury.
 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Содержание BS-PY82L-120DC

Страница 1: ...PY L DC Brushless Sliding Gate Opener INSTALLATION MANUAL USER GUIDE ...

Страница 2: ...ges etc may be used to prevent any potential risk in dangerous areas where the moving mechanism is located such as crushing dragging or shearing BS accepts no responsibility regarding safety and correct operation of the machine should components made by manufacturers other than we be used in the system Do not make any alterations to the components of the automatic machine opener and accessory The ...

Страница 3: ...d out if the appliance is automatically controlled The temperature range marked on the drive should be suitable for the location The electrical cord plug must plug in indoor outlet or waterproof cover outlet Ensure that entrapment between the driven part and the surrounding fixed parts due to the opening movement of the driven part is avoided After installation ensure that the mechanism is properl...

Страница 4: ... control board Terminals for Push button Photocell Alarm lamp Auto closing is available time delay is adjustable 1 Gearbox 2 Release Clutch 3 DC Motor 4 Electromagnetic Brake 5 Transformer 6 LED Light 7 Motor Cover 8 Gear Reducer 9 Control Board 10 Limit Switch 11 Output Pinion ...

Страница 5: ...30m 1 4 Feature 1 3 Technical Specifications 1 The eletromagnetic brake could lock the operator when power off 2 In case of power failure the gate can be opened and closed manually after release clutch 3 Soft start function 4 Reverse or stop when meet obstacle the two functions is optional 5 Soft stop or limit brake function is optional 6 Auto close delay function 7 Applicable to access control sy...

Страница 6: ...nstalled by professional person Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules The diameter of wire on the wall not less than 1mm the diameter of wire that con nect to appliance not less than 0 5mm The external diameter of power line not more than 14mm the power line should have polychloroprene sheathed cable and at least normal polychloroprene...

Страница 7: ...he baseplate Key Ensure baseplate on level position M8 Bolt Door opener Base Plate 2 2 installation and adjustment Bolt Output pinion of sliding gate opener Rack 1 7 3 m m 300mm 20mm B A C Power 300mm Baseplate Baseplate Wheel Slide way Gate Rack Expansion Bolt Concrete base ...

Страница 8: ... magnet on the rack the gear box of the operator must be released asper Fig7 use the key turn clockwise to release the gear release key unlock lock release cover 2 3 Power Connection Rack Gate Output Pinion Wheel Slide way Gasket Base plate Fig7 Concrete base ...

Страница 9: ...play 1 2 3 4 ON DP Dip switch Function Opening Closing Stop Reach open limit Reach close limit Set transmitter LED Set transmitter button DIP Switch Loop Close Stop Open Photoccll Close limit Open limit Electromagnetic Brake Motor wires Transformer 24V input LED Alarm Lamp Yellow Green Blue 10A Fuse Airwave switch Receiue Trans mitter Y G B 3 Control board Display ...

Страница 10: ...it set interface Px setting X 1 9 No Parameter Description Protect time for motor running unit second motor will stop when over time Motor speed Lever 1 to 5 Min 1 Max 5 Reduce speed distance 0 15 Sensitivity of reverse when obstacle 0 50 Limit set 0 Normal Open 1 Normal Close Auto close delay time 0 99 0 no Auto close Sofe stop reduce speed 1 5 1 Fastest 5 Slowest Sofe stop 0 no Soft stop 1 valid...

Страница 11: ...ll 1 Change limit magnet 2 Rectify limit magnet 3 Adjust the magnet pole 1 Check power supply 2 Change fuse 3 Change capacitor 4 Check if any barrier on track 5 Restart after 20 minutes 4 2 2 Erase travel Gate opener must relearn travel and limit position method is power on operate the opener open and close one time don t push stop or don t active photocell if display YS means learning successfull...

Страница 12: ...t Check motor wires connectors Move away the obstacle or adjust the reverse level Remove the object that block the photocell Remove the obstacle orcheek the motor Restart or change the control board Check the hull connectors or change the motor Error Codes 6 Maintain 1 Frequently cheek the wires connectors especially the outter connetors 2 Check the GND make swire connection are as required 3 Chec...