Legacy RS-232 Commands
25
Table 7 Prefix Examples
T
riggers
(Tx)
Table 8 Trigger Conditions
Data String
Description
NFC.0.123W(CR)(LF)
Normal (N) forward carrier wave (FC), prefixes on
OFC 199.9W(CR)(LF)
Overflowed (O) forward carrier wave (FC), prefixes
on
199.9W(CR)(LF)
Overflowed forward carrier wave, prefixes off
URC .000W(CR)(LF)
Underflowed (U) reflected carrier wave (RC),
prefixes on
Function
Selects the condition which will trigger a reading (see
).
Remarks
Failure to trigger device before requesting a reading will lock
the bus.
Fastest reading rate is 2.4 readings/second; slowest is 1
reading/sec.
Command
Trigger Condition
T1
One shot on ENT
T5
One shot on measurement command (FC, FD, RC,
RD, SW, RL, MN, MX)
Содержание SMK-3000 Series
Страница 2: ......
Страница 38: ...RF Calibration Kit 28 Figure 13 Sensor Accuracy Vs Load VSWR...