Installation
12
Panel Mount
WARNING
Disconnect the unit from the RF power source and the AC line before any
disassembly. The potential for electrical shock exists.
CAUTION
The +15V supply should only be used to power the ACMI Panel. Do not
connect anything else to the power supply.
Installation
To install a Bird Antenna Monitor in the rack mount, follow these instructions
(Refer to
1.
Unbuckle the Velcro strap and move the power/alarm connector out of the
way.
2.
Place the ACMI on the panel so that the screws on the bottom of the
Monitor fit into the locator holes on the panel.
Note:
The ACMI should lock into place.
3.
Use the strap to secure the ACMI.
4.
Plug the power/alarm connector into the power/alarm parallel port on the
ACMI.
5.
Make RF and Ethernet connections as described in this chapter.
Ethernet Connector
Note:
Max. Ethernet cable length must be <50m.
The Ethernet connector carries data between the Antenna Monitor and a PC.
When connecting to the ACMI using the Ethernet port, you use the Web Tool
software to setup the ACMI. You do not need to install the Web Tool software
because it is part of the ACMI firmware.
In order to determine the IP address of the ACMI, the ACMI Finder utility will
need to be installed.
Note:
You must have Java runtime environment version 7 (JRE v7)
or higher installed before you can use the Web Tool or Finder soft-
ware.