Maintenance
39
Cord Reel (Cal Cart only)
1. Disconnect the cord reel from the terminal strip.
2. Unscrew the AC connector.
3. Unscrew and remove the cord reel.
4. Screw the replacement cord reel into place.
5. Thread the AC connector through the grommet, and connect the wires on
the other end to the terminal strip (See Figure 18).
Replacing Fuses
1. Gently pry the fuse drawer out of the ac module. The fuse holder does not
detach from the AC module.
2. Install the replacement fuses then close and secure the fuse holder. Fuse 1
is a spare fuse and fuse 2 is the active fuse.
Figure 18 AC Line Fuse
WARNING
To avoid personal injury, disconnect the power cord from the ac line before
performing any maintenance, including fuse replacement.
CAUTION
Failure to install the properly rated fuse may result in equipment damage or
nuisance failures.
AC Line Voltage
Fuse Rating
115 Vac
T630 mA, 5x20 mm Time Lag Fuse
230 Vac
T315 mA, 5x20 mm Time Lag Fuse
Fuse 1
Fuse 2
Fuse
Drawer
AC Module