background image

Address

320 B Percheron Road, Kyalami, Midrand, 1684

 

GPS Coordinates:

 

S 25.98115º / E 028.06869º

 

 

 

BirCraft 

GEARED MOTORS - LINEAR ACTUATORS - CONTROLS 

 
 
 
 

 

t:

 

+ (27) 011 468 1881 

c:

 

+(27) 074 465 1744 

 

 

 

e:

 

01@

BirCraft

.co.za 

w:

  

www.

BirCraft

.co.za

 

 

 

 

 

 

 

 
 
 

GUIDELINE DIMENSIONS ONLY 

 

- Over 

40 Years

 of Supplying Africa - 

Variable DC Speed Drives 

 Operation Manual 

 

 BADCD

12

-10 and BADCD

24

-10 

 
 
 
 
 
 
 
 
 

 

Contents

 

Safety Precautions: .............................................................................................................................................................................................................................. 1 
Specification and Model: ..................................................................................................................................................................................................................... 1 
Product Characteristics: ....................................................................................................................................................................................................................... 2 
Installation Requirements: ................................................................................................................................................................................................................... 2 
Performance Indexes: .......................................................................................................................................................................................................................... 2 
Wiring Requirements: .......................................................................................................................................................................................................................... 3 
Driver Terminal Function Diagram: ...................................................................................................................................................................................................... 3 

Description of control Terminal’s Functions:

 ....................................................................................................................................................................................... 3 

EN (Enable Control) .................................................................................................................................................................................................................... 3 
DIR (Direction Control) ............................................................................................................................................................................................................... 3 
C E (OC Door Alarm Output) ....................................................................................................................................................................................................... 4 

4. S1 S2 S3 Signal Output Terminal: ..................................................................................................................................................................................................... 4 
Description of Indicator: ...................................................................................................................................................................................................................... 5 
Regulation Description of Functional Potentiometer: .......................................................................................................................................................................... 5 
Driver Examination steps before Charged: .......................................................................................................................................................................................... 5 
Common Fault Treatment: ................................................................................................................................................................................................................... 5 

 

 

Safety Precautions: 

 

 

Installation, connection and commissioning of this device shall be carried out by professionals. 

 

Do not install, remove or replace device circuit under charged circumstances. 

 

Please make sure that necessary protectors are mounted between power input end of this device and power supply 
(storage battery) to avoid accidents or fatal damages; Devices need to be mounted: over-current protector, fuse, 
emergency switch. 

 

Isolation and insulation protection between device and ground as well as devices shall be well equipped. 

 

In case that charged commissioning of this device is really needed, well-insulated non-metal special screwdriver or 
special commissioning tools shall be used. 

 

This device shall be installed in well-ventilated environment. 

 

This device shall not be directly exposed to abnormal environments with high humidity, dust, corrosive gas and intense 
vibration. 

Specification and Model: 

 
 

 

PRODUCT #: 

CONTINUOUS OUTPUT CURRENT 

DC (A): 

MAX OUTPUT CURRENT 

 DC (A): 

DC VOLTAGE WORKING RANGE 

10-18 DC (V): 

BADCD

12

-10 

10 

20 

10 - 18 

BADCD

24

-10 

10 

20 

20 - 55 