Wiring Requirements: 

 

Do not connect wire under charged. 

 

Insulated connection, shielded wire which match with 

driver’s voltage current shall be selected and connected, 

specifications of driver’s power input wire and motor’s wire are shown below:

 

 

Table 1 Wire Specification and Length Table 

CURRENT (A) 

WIRE SPECIFICATION (MM2) 

MAX. LENGTH (M) 

10 

1.5 

15 

20 

2.5 

15 

 

 

Signal line and control line shall adopt shielded wire and shall be separated with power input wire and output wire.

 

 
 
 

 

 

The driver does not have internal power supply reverse connection protection function, make sure that wiring between 
power input and driver is correct, otherwise the driver may be damaged. 

 

Proper tools shall be used for wiring and make sure that wiring is correct.

 

 

Driver Terminal Function Diagram: 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Description of control 

Terminal’s 

Functions: 

EN (Enable Control) 

During motor operation, simply connect/ disconnect EN with COM to control the start and stop of motor 
Connect EN terminal with COM, EN terminal is effective, at this time regulate external speed potentiometer and 
motor is in normal operation. 
EN terminal suspends in the air or is not connected, EN terminal is invalid; circuit of controller is blocked and motor 
stops. 

 

DIR (Direction Control) 

 

During motor operation, simply connect/ disconnect EN with COM to reverse the motor rotation. It doesn

t need 

external reversing contactor and will not result in electric motor parts or other components overheating or burning 
down. 
Connect DIR terminal with COM, DIR terminal is effective, motor is in negative rotation. 
DIR terminal suspends in the air or is not connected, DIR terminal is invalid; motor is in positive rotation (runs in 
opposite direction as above mentioned). 

 In any cases, signal line and logic control line shall not be bound,  mixed and wired with power input wire,  output wire 
(motor line) and other power lines. Induced voltage generated may cause interface, malfunction or directly damage the 
driver. 
 