Variable Speed Drives 

 Operation Manual   

BADCD12-10 and BADCD24-10

 

- Over 

40 Years

 of Supplying Africa - 

GUIDELINE DIMENSIONS ONLY 

 

C E (OC Door Alarm Output) 

The internal design of 

OC door alarm output

 is that over

current signal is transmitted through an opto

coupler to 

give alarms. When over

current is detected on the controller, over

current signal will be immediately sent to diode 

of opto

coupler for break over and then transmitted to C, E ports. The client can wire as their own requirements, as 

shown in Figure 1, connect to over

current indicator, Figure 2, relay actuation after over

current to give alarms. 

Internal wiring diagram of 

OC door alarm output

 is shown as follows: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4. S1 S2 S3 Signal Output Terminal: 

 
Such controller has two control modes of external speed potentiometer control and external analogue quantity input. 
Description of various terminals is as follows: 

 

S1 Terminal: external power+10V 

 

 

S2 Terminal: signal input terminal

 

 

S3 Terminal: GND (grounded).

 

 

When external speed potentiometer control is used, S1, S2, S3 terminals shall be connected with external potentiometer as 
shown in VI. Driver terminal function diagram to regulate external potentiometer for speed governing 
 

When external analogue quantity input control is used, speed can be controlled through S2 and S3 input, both 0‐

 

5V and 0‐10V 

are OK. 
 
 
 
 
 
 
 
 
 
 