Extended configurations, factory settings
3
Operation with testing (cat. 2 acc. to EN ISO 13849-1)
3.1
DIP switch setting:
Test NO contact (test activated = contact closed)
Test NC contact (test activated = contact open)
Factory settings
Connection possibilities:
On controller: contact
PNP- or NPN-transistor
Applications with limit switch (bridges the safety edge!)
3.2
Wire up transmitter to limit switch
RFGate 2.1.S
RFGate 2.1.S.F
Output NO instead of 8.2 kohm resistor
3.3
On both relay outputs, the 8.2 kohm resistor can be disconnected if required by removing a jumper.
with
Jumper:
without
Jumper:
Jumper output 1:
Jumper output 2:
Overview tables for DIP switches
3.4
Receiver:
Transmitter:
1
1
3
3
2
2
4
4
5
5
ON
ON
1 ON
Default setting
5
5
1
1
3
3
2
2
4
4
ON
ON
1 OFF
No safety operation!
5
5
2
2
3
3
1
1
4
4
ON
ON
2 ON
869.85 MHz
5
5
2
2
3
3
1
1
4
4
ON
ON
2 OFF
868.95 MHz
5
5
3
3
1
1
2
2
4
4
ON
ON
3 ON
Test input NC
5
5
3
3
1
1
2
2
4
4
ON
ON
3 OFF
Test input NO
5
5
4
4
1
1
2
2
3
3
ON
ON
4 ON
Frequency adaptation on
5
5
4
4
1
1
2
2
3
3
ON
ON
4 OFF
Frequency adaptation off
1
1
2
2
3
3
5
5
4
4
ON
ON
5 ON
Default setting
4
4
5
5
1
1
2
2
3
3
ON
ON
5 OFF
No function!
1
1
2
2
ON
ON
1 ON
Safety edge
with 8.2 kOhm
1
1
2
2
ON
ON
1 OFF
Contact NO (s. 2.6)
2
2
1
1
ON
ON
2 ON
869.85 MHz
2
2
1
1
ON
ON
2 OFF
868.95 MHz
Factory settings
3.5
For safety operation
Receiver:
Transmitter:
Important:
Receiver switches 1 and 5
always
in
ON
position.Correct
operation is not guaranteed if OFF!
Factory settings