Trouble shooting

   Issue

Possible cause

   Solution

   – Increase the frontal angle of the radar module
   – Install sensor higher and if possible directly above the door hinge
   – Increase CTA level
   – Rotate the sensor in the direction of the door opening
   – Activate the interference suppression filter                     

   – Activate the special filter function MTO

      (Mass Traffic Optimization)

   – Decrease the CTA level (switch off)
   – Check field size
   – Activate high mounting height                     

Refer to chapter

   6.1.1
   
   5.2.3
   6.1.1
   5.2.3

   5.2.3
   

   5.2.3

   Door does not close / reverses
   Door does not close / reverses

   Door opens inadvertently

   Door does not open – 
   random non-detection
   of an individual
   Late detection or                            
   non-detection of persons

   – Sensor sees sliding door
   – Sensor sees swing door

   –  Interference source affects microwave field  
       (e.g. fluorescent tubes)
   – Large group of persons                 

      approaching

   – Field too small
   – Installation too high

7

7.1

Mechanical Settings of the Sensing Field

Frontal adjustment

7.2

Lateral adjustment

9

Technical Data

   

Technology

   Transmitting frequency

   Transmitting power

   Operating voltage

   Operating current

   Mains frequency

   Temperature range

   Air humidity

   Mounting height

   Relay output

   Switching voltage                          

   Switching current                          

   Switching capacity

                     

   Housing

   Weight

   Protection class
   Minimum detection

speed

   Cable length

   Overview of countries

   Microwave motion detector with 

planar module technology

   24.125 GHz

   < 20 dBm

   12–36 V DC / 12–28 V AC 

   approx. 50 mA @ 24 V DC, 75.2° F

   50 Hz

   –4° F to + 140° F

   0 to 90 % rel., without condensation

   up to 13.12 ft

   Potential-free changeover contact

   max. 48 V ACDC

   max. 0.5 A AC / 1 A DC

   max. 60 VA / 30 W
   Cover: PC; floor plate: ABS
   Dimensions (W x H x D): 
   6.93 x 2.44 x .20 inches 

   5.29 ounces (without cable)

   Suitable for use acc. to IP 54
   1.97 in/s (in sensor axis)
   < 1.97 in/s with SMD+ 
   (inclination angle 35°)

   9.84 feet

   EU; EFTA; US; CA

45°

–30°

+30°

45°

–30°

+30°

   

+     +     

F

6

1

   

+     

B

4

D

   

+     +     

F

4

1

2

2

2

9

9

8

S

  

  

0

3

/1

7

If after troubleshooting a problem, a satisfactory 
solution cannot be achieved, please call:
Bircher Reglomat 

    

at 800- 252-1272 

from 8am - 5pm central standard time.
You may also visit our website at: 

www.bircherreglomat.com
DO NOT LEAVE ANY PROBLEMS UNRESOLVED
NEVER SACRIFICE SAFETY FOR ANY REASON

Bircher Reglomat reserves the right to change any information on this docu-
ment without notice. 
For the latest version, please log on to www.bircherreglomat.com or call us
at 847-952-3730 to request a copy of the current version.

10

Contact

11

13

12

Disclaimer

FCC Approval

EC-Declaration of Conformity

This device complies with Part 15 of the FCC Rules and with RSS-210 of
Industry Canada
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Warning: Changes or modifications made to this equipment not expressly
approved by Bircher Reglomat AG may void the FCC authorization to operate
this equipment.

4

Manufacturer: 

Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen

Importer: 

Bircher America, Inc. 870 Pratt Ave N, Schaumburg, IL 60193, USA, www.bircherreglomat.com

Following directives have been observed:  RoHS 2011/65/EU, RED 2014/53
Standards taken into account:

EN 300 440-1 V1.61:2010-8, EN 300 440-2 V41.41:2010-8

Отзывы: