Parameter
Direction recognition [ES]
Field size
Relay hold interval
Output signal
SMD function
Mounting height
Cross traffic
Interference suppression
SMD field size
Field geometry
C
1
+ *
+
C
2
+
C
3
+
C
4
+
C
5
+
C
6
Standard
ON, forwards
6
1 sec
Active
Off
Up to 10 feet
Low
Off
1
Wide
Sidewalk
ON, forwards
7
0.8 sec
Active
Off
Up to 10 feet
Medium
Off
1
Narrow
High-risk
OFF
6
2 sec
Active
Decreasing, 2 s
Up to 10 feet
Off
Off
5
Wide
Vestibule
ON, forwards
6
0.2 sec
Active
Off
Up to 10 feet
Low
Off
1
Narrow
Retail
ON, forwards
9
1.5 sec
Active
Decreasing, 2 s
10 - 13 feet
Off
Off
5
Wide
ON, forwards
9
1 sec
Active
Off
10 - 13 feet
Medium
Off
1
Wide
3 m
(9.84')
>
Key code
Key
code
Parameter
Level
Short description
Convenience
functions
1*– 6
Predefined settings for standard
applications (see table)
Values measured with mounting height 7.22 feet and tilt angle 35°.
SMD = Slow motion detection: Very slow movements are detected as soon as
the sensor is activated. Only when no more movements are registered during the
set monitoring period does the sensor relay the corresponding signal to the door
controller. The sensitivity during this monitoring period can be set to decreasing
or constant.
Min. 3.61 x 1.97 ft (W x D)
Max. 15.42 x 5.58 ft (W x D)
* Factory setting
Convenience functions
Configuration of individual parameters
Field size / field geometry
D
+
F
8
Depending on the field geometry (wide/narrow field), the field size can be set
correspondingly.
Narrow
field:
Wide
field:
SMD function and SMD+
+
F
3
SMD+: Triggers the sensor when very slow movements occur.
Even objects slower than 2”/s (35° inclination angle) that are
not detected with the normal detection area are detected
(suited for high-risk facilities). In order to prevent the door
from being kept open too long, the SMD+ field is half as large
as the detection area.
SMD field size
+
F
7
The SMD field size is approximately the same as the regular sensing field.
The CTA prevents a door from being inadvertently opened by people who walk
by it but do not want to enter.
+
D
5
+ +
~
F
7
5
Cross traffic optimization CTO
+
F
5
6.5
Status query with remote control
The status query is used to find out what parameters have been set. For this to
take place, the connection to the sensor has to be established and the
corresponding key code has to be entered. After that, a numerical key lights up
indicating the respective parameter level.
+
F
4
C
B
D
+
F
8
+
F
1
+
F
2
+
F
3
+
F
7
+
F
5
+
F
6
B
D
+
F
1
+
F
2
+
F
3
+
F
4
+
F
5
+
F
6
+
F
7
+
F
8
~
6.4
Explanation of individual parameters
Recommendation: First, select the enhanced function that is closest to the requirements and then change the parameter levels correspondingly.
B
T
B
T
Min. 2.30 x 1.97 ft (W x D)
Max. 8.86 x 6.23 ft (W x D)
Direction recognition
(only with Reflex 2
ES)
Off
Backwards
Forward
Forwards with MTO (see chap. 8)
1
2
3*
4
1
2*
1
2*
1 – 3
4 – 6*
7 – 9
1
2
3
4*
5
6
7
8
9
1*
2
1*
2
3
4
5
6
7
8
- 9
1*– 3
4 – 6
7 – 9
1
2*– 3
4 – 6
7 – 9
1
2*
On
Prevention of false detections
from fluorescent tubes.
Off
Off
Low
Medium
High
Small
Medium
Large
Off
0.5 s
1.0 s Decreasing sensitivity
1.5 s
2.0 s
0.5 s
1.0 s Constant sensitivity
1.5 s
2.0 s (SMD+)
NO: The relay picks up when a detection takes place
NC: The relay drops out when a detection takes place
Small
Medium
Large
0.2 s
0.5 s Short
0.8 s
1.0 s
1.5 s Medium
2.0 s
Narrow field
Wide field
High (10-13 feet)
Standard (up to 10 feet)
Mounting height
Field geometry
Field size
Output signal
Relay hold-time
SMD function
SMD field size
CTO
(cross traffic
optimization)
Filter for
interference
suppression
3
High mounting
2.5 s
3.0 s Long
4.0 s
Optimum sensor settings:
-Narrow field
-Inclination angle 30° – 45°