5
Manual Settings
Without specific address:
Parameter
Step 1
Step 2
Field size
Functionality
Field geometry
Press [<] briefly
Press [>] briefly
Press [<] and [>] briefly at the same time
# of flashes of the
green LED (1-9 times) indicates
the current parameter level
Note:
If no key is touched for 25 seconds, the configuration mode is automatically exit-
ed and the green LED briefly flashes. The settings created up to that point are
saved.
How to find out the value of each parameter.
5.1
Sensor parameters status
6.2
Mode of operation
Activation: – After connecting the sensor to the power supply
or
– Briefly disconnect the sensor from the power supply
or
– Press either key [<] or [>] on the sensor
Exiting: – Press key combination
or
– Automatically after 30 Minimum.
Note:
If no button is pushed for 30 seconds, the connection is closed. The settings
made up to that point are saved.
1, 2, 3 small
4, 5, 6* medium
7, 8, 9
large
for Reflex 2 version with direction recognition
Le
ve
l
1*
detects approaching targets, mounting height standard
2
detects approaching targets, mounting height high
3
detects going away targets, mounting height standard
4
detects going away targets, mounting height high
5
direction recognition OFF, mounting height standard
6
direction recognition OFF, mounting height high
7
ap MTO, mounting height standard (MTO, see chap. 8)
8
ap MTO, mounting height high (MTO, see chap. 8)
1
narrow field
2*
wide field
Changing the functionality from level 6 to level 2:
1) Keep [<] and [>] pressed for 4 seconds, the green LED blinks once after
2 seconds, once again after 4 seconds
2) Green LED flashes 6 times, indicating the current parameter level
3) Press the key [<] four times in a row to decrease the parameter level
(green LED flashes twice and indicates the new parameter level)
4) Press [<] and [>] at the same time
The data transmission to and from the sensor is ensured by an IR interface. The
connection between the remote control and the sensor can only be established
when the sensor is in configuration mode.
With specific address:
1. Press the start key
1. Cover the IR interface of the
remote control with your hand
2. Press the start key >
flashes
3. Release the IR interface
(remove hand)
4. Press the corresponding numerical
key ( to )
– G and one of the keys 1 through 4 light up:
Connection successfully
established
–
G flashes:
Connection not established
> Activate configuration mode (see above)
> Hold remote control closer to the sensor and point directly at it
> Check batteries in remote control
– No keys light up
> Check/replace batteries in remote control
6.3
Setting / changing parameters
Door open: Keeps the door open manually for 15 Minimum.
Afterwards, the door will close if no object is in the detection area.
Door closed: Door closes if no object is in the detection area,
afterwards standard operation.
After the connection has been successfully established, the parameters of the
sensor can be changed.
General procedure
[>]
[<]
Changing the field size:
Press [<] and [>] for 2 seconds
Changing the functionality:
Press [<] and [>] for 4 seconds
for Reflex 2 version without direction recognition
1*
mounting height standard
2
mounting height high
Changing the field shape: Press [<] and [>] for 6 seconds
Example
Restore factory settings:
Press [<] and [>] for 8 seconds
Configuration mode
+
A
3
Establishing the connection
Each sensor can be assigned an address (1*, 2, 3 or 4). Different addresses are
necessary when several sensors are within the range of a remote control.
Address 1*
Address 2
Address 3
Address 4
6.1
Sensor addressing
G
G
G
1
4
+
A
1
+
A
2
+
A
3
Numerical keys to
1
9
IR interface (infrared)
Control keys to
A
F
Start
G
1) Keep [<] and [>] pressed for an equal length of time, every 2 seconds the
green LED will flash once
2) # of flashes of the green LED (1–9 times) indicates current parameter level
3) The parameter level can be decreased or increased with [<] and [>]
respectively
4) Press [<] and [>] briefly to exit the configuration mode (settings are saved)
Le
ve
l
Le
ve
l
Le
ve
l
2
* Factory setting
6
Remote Control Settings
Exit configuration mode: Configuration mode is ended, door closes
when no object is in the detection area, afterwards standard opera-
tion.