Installation instructions
Motion sensor for automatic doors
Questions? Call us at 800 - 252-1272, 8am – 5pm central standard time.
1
Safety Instructions
4
Displays on the Sensor
Red LED
Grooves for mounting screws
Base cover
Cable feed-through
DIP switch (for addressing)
Key [<]
Key [>]
9
10
11
12
13
14
8
Cover
Plug-in screw terminal
RJ12 PCB socket
Ring for lateral adjustment
Frontal adjustment
Radar double field antenna
Green LED
2
3
4
5
6
7
1
3.2
Opening the housing
– Mount sensor on a flat stable surface (avoid vibrations)
– Do not expose sensor to rain or snow
– Objects (e.g. plants, flags, fans etc.) must be kept out of sensing field
– Do not place any cover in front of the sensor
– Do not place fluorescent tubes near the detection area
3
Installation
3.1
2
3.3
Mounting
Place drilling template on wall/ceiling and drill holes
Route cable through the appropriate opening in the base cover –
make sure length is sufficient for wiring
Install sensor with screws
Connect cable (see chap. 3.4)
Click cover on base cover
2
3
4
5
1
3.4
Electrical connections
Reflex 2 with plug-in screw terminal
Reflex 2 with RJ12 PCB socket
green
blue
black
white
red
yellow
common
NO
NC
+ 12-36 V DC
- 12-28 V AC
not connected
+
12-28
2
Description of the Sensor
1
1
6
12
2
3
14
8
7
5
9
11
10
brown
blue
black
white
1
2
3
4
5
12-36
12-28
+ 12-36 V DC
- 12-28 V AC
common
NO
NC
9
13
2
4
Start-up phase
Configuration
Operation
Red LED
Lights up during startup for 3 seconds
4
Green LED
Afterwards, the green LED flashes a few times and indicates the
software version (the sensor is already functional and
programmable)
Reflex
2
motion
* The device must only be operated at a protective low voltage with safe electrical insulation. Product repairs must be performed solely by the manufacturer.
* Shut off all power going to the sensor before attempting any wiring procedures.
* Maintain a clean & safe environment when working in public areas.
* Constantly be aware of pedestrian traffic around the door area.
* Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
* Always check placement of all wiring and components before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
* Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
D O N O T L E A V E A N Y P R O B L E M S U N R E S O L V E D - N E V E R S A C R I F I C E S A F E T Y F O R A N Y R E A S O N
User’s guide
LED red
Lights up upon detection
Green LED Lights up when SMD is active
Green LED
– Indicates parameter or parameter level through
# of flashes (with key configuration)
– Flashes briefly:
– When key configuration mode is exited
– When the sensor has received the command from
the remote control
1
5
3
3
BEFORE installation
AFTER installation