background image

Power supply

12–36 V DC / 12–28 V AC

Current consumption 

approx. 70 mA at 24 V AC

Temp. range

–4 °F to +140 °F)

Humidity

0 to 90% rel. 

Microwave module

K-band 24,125 GHz +/– 100 MHz

Transmitting power

< 20 dBm

LEDred = Detection activated    green = for adjusting functions

Relay output pot. free

change-over contact

Switching voltage

48 V AC/DC

Switching current

0.5 A AC/1 A DC

Switching power

60 VA / 30 W

Protection class

suitable for the application after IP 54

Housing material

ABS 

Recommended maximum mounting height

13.12'

If after troubleshooting a problem, a satisfactory

solution cannot be achieved, please call 

Bircher Reglomat at 800 - 252-1272 

from 8am - 5pm central standard time.

You may also visit our website at

www.bircherreglomat.com

DO NOT LEAVE ANY PROBLEMS UNRESOLVED

NEVER SACRIFICE SAFETY FOR ANY REASON

Technical data

M

6

A1

ca. 15 min.

A2

Manual door opening & closing [through the sensor remote]

K

Interferences avoidance: vibration, wind, rain.

L

on

off

F

5

1

9

F

6

1

F

6

2

on

off

suggested module
position > 30°

3 m

(9.84')

>

>

F

4

1

3 m

(9.84')

on

2

1

2

2

= active

= passive

Relay switches on upon detection

Relay switches off upon detection

Contact

N

Bircher Reglomat reserves the right to change any

information on this document without notice. 

For the latest version, please log on to

www.bircherreglomat.com 

or call us at 847-952-3730 to request a copy of the

current version.

Disclaimer

O

NO / NC

Amplification level 1 for high mouting or wide field [max. mounting height 13 feet]

high mouting

>9.84’

(3 m)

Cross traffic optimization

Interference filter

approx. 15 min.

<

<

F

4

2

3 m

(9.84')

  3 m

(9.84')

<9.84’

(3 m)

< 9.84’ (3 m)

wide field

off

> 9.84’ (3 m)

Содержание Reflex ES

Страница 1: ...nsure that moving door parts will not catch any wires and cause damage to equipment Ensure compliance with all applicable safety standards i e ANSI A156 10 upon completion of installation Safety instructions Microwave motion detector for automatic pedestrian doors with direction recognition Questions Call us at 800 252 1272 8am 5pm central standard time 1 2 3 4 5 1 2 5 4 3 Installation flash press...

Страница 2: ...ectionrecognitionon 5 Directionrecognitionoff standard 6 Directionrecognitionoff high 1 x 1 9 F E E F x 1 6 x 1 x 1 1 x 1 x 1 3 Sensitivity adjustment completion Function adjustment completion Manual Set up w o RC Duo remote control B 3 4 4 2 convenience function check convenience function setting x 1 x 1 x 1 9 2 sec Stufe Step 1 2 3 4 5 6 7 8 9 sensitivity level check Connections RJ12 Plug in scr...

Страница 3: ... sec Testing of the settings Measure by walking according to ANSI 156 10 D The use of the clip requires the amplification F41 Use the clip for wide fields according to the table on the left At mounting heights above 10 wide fields are set using the frontal inclination angle section C1 and the sensitivity section H Other field adjustments normal and wide detection field After removing or putting th...

Страница 4: ...ection is automatically interrupted after 30 min To restore the connection see next 1 2 Sensor address lights up 1 to 4 4 Establish connection between the RC Duo remote and the sensor Restore communication with the RC Duo if it turned off after 30 minutes power off and on OR press a push button direct remote control towards the sensors Multiple sensors set up assign a unique address to each F3 slo...

Страница 5: ...ield with clip min 1 64 0 5 m max 8 20 2 5 m min 1 64 0 5 m max 8 20 2 5 m min 3 28 1 0 m max 13 12 4 0m min 1 64 0 5 m max 6 56 2 0 m Adjusting the width of SMD area 7 1 9 Hold time setting B 2 B 1 E 2 B 1 E 2 B 2 B 1 E 1 B 1 E 1 Direction recognition G B with direction recognition D medium F1 short F2 active F3 off F4 standard F5 low F6 off B with direction recognition D high F1 medium F2 active...

Страница 6: ... bircherreglomat com DO NOT LEAVE ANY PROBLEMS UNRESOLVED NEVER SACRIFICE SAFETY FOR ANY REASON Technical data M 6 A 1 ca 15 min A 2 Manual door opening closing through the sensor remote K Interferences avoidance vibration wind rain L on off F 5 1 9 F 6 1 F 6 2 on off suggested module position 30 3 m 9 84 F 4 1 3 m 9 84 on 2 1 2 2 active passive Relay switches on upon detection Relay switches off ...

Страница 7: ...adiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a paticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Отзывы: