background image

1

- 12 - 24 V AC - 0%/+15%

+ 12 - 30 V DC - 0%/+15% 

common

NO

NC

K

6

2

0

2

.0

2

9

0

4

/0

7

Potentiometer for 
scanning range setting

4b

4c

4a

EN

EN

TS

TS

4

Adjustments

Jumper EN

Pos. N= 1.97"–7.87" (50-200 mm)*

Jumper TS

Pos. T=scanner

Jumper EN

Pos. E= 1.97"–23.62" (50-600 mm)*

Jumper TS

Pos. S=switch ON/OFF

Attention: After adjustment of the scanning range/mounting of the cover, turn off power for approx. 5 seconds, and then turn it on again.

*standard settings

5

Wiring diagrams

6

Technical Data

If after troubleshooting a problem, a 
satisfactory solution cannot be achieved,
please call:
Bircher Reglomat at 800- 252-1272 
from 8am - 5pm central standard time.

You may also visit our website at: 
www.bircherreglomat.com

DO NOT LEAVE ANY PROBLEMS UNRESOLVED
NEVER SACRIFICE SAFETY FOR ANY REASON

Bircher Reglomat reserves the right to change
any information on this document without
notice. 

For the latest version, please log on to 
www.bircherreglomat.com 
or call us at 847-952-3730 to request a copy of
the current version.

7

Contact

8

Disclaimer

9

FCC Approval

- This Class B digital apparatus complies with  

Canadian ICES-003. Cet appareil numérique de la 
classe B est conforme à la norme NMB-003 du   
Canada. 

- This device complies with part 15 of the FCC  

Rules.  Operation is subject to the following 
two conditions:

1. This device may not cause harmful 

interference, and

2. This device must accept any interference   

received, including interference that may 
cause an unwanted operation. 

Adjustable Short Range   

(enhanced sensitivity)

Adjustable Long Range    

(standard sensitivity)

B/W Difference
Power supply

Current consumption
Temperature range
Atmospheric Humidity
Relay Output

Switching voltage
Switching current
Switching capacity

Function indication
Protection class
Protection class with sealing
Electromagnetic compatibility

1.97” - 7.87” (50 - 200 mm)*                             
1.97” - 23.62” (50 - 600 mm)                             
approximately 10%
12 - 24 V AC - 0%/+15%
12 - 30 V DC - 0%/+15%
approximately 50 mA
-4° to 140°F  (-20° to 60°C)
0 to 90% rel.  

48 V AC/DC
1 A
30 W/60 VA
LED (red “on” when active)
IP 52
IP 65
EMC dir. 89/336/EEC

*standard settings