1
- 12 - 24 V AC - 0%/+15%
+ 12 - 30 V DC - 0%/+15%
common
NO
NC
K
6
2
0
2
.0
2
9
0
4
/0
7
Potentiometer for
scanning range setting
4b
4c
4a
EN
EN
TS
TS
4
Adjustments
Jumper EN
Pos. N= 1.97"–7.87" (50-200 mm)*
Jumper TS
Pos. T=scanner
Jumper EN
Pos. E= 1.97"–23.62" (50-600 mm)*
Jumper TS
Pos. S=switch ON/OFF
Attention: After adjustment of the scanning range/mounting of the cover, turn off power for approx. 5 seconds, and then turn it on again.
*standard settings
5
Wiring diagrams
6
Technical Data
If after troubleshooting a problem, a
satisfactory solution cannot be achieved,
please call:
Bircher Reglomat at 800- 252-1272
from 8am - 5pm central standard time.
You may also visit our website at:
www.bircherreglomat.com
DO NOT LEAVE ANY PROBLEMS UNRESOLVED
NEVER SACRIFICE SAFETY FOR ANY REASON
Bircher Reglomat reserves the right to change
any information on this document without
notice.
For the latest version, please log on to
www.bircherreglomat.com
or call us at 847-952-3730 to request a copy of
the current version.
7
Contact
8
Disclaimer
9
FCC Approval
- This Class B digital apparatus complies with
Canadian ICES-003. Cet appareil numérique de la
classe B est conforme à la norme NMB-003 du
Canada.
- This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful
interference, and
2. This device must accept any interference
received, including interference that may
cause an unwanted operation.
Adjustable Short Range
(enhanced sensitivity)
Adjustable Long Range
(standard sensitivity)
B/W Difference
Power supply
Current consumption
Temperature range
Atmospheric Humidity
Relay Output
Switching voltage
Switching current
Switching capacity
Function indication
Protection class
Protection class with sealing
Electromagnetic compatibility
1.97” - 7.87” (50 - 200 mm)*
1.97” - 23.62” (50 - 600 mm)
approximately 10%
12 - 24 V AC - 0%/+15%
12 - 30 V DC - 0%/+15%
approximately 50 mA
-4° to 140°F (-20° to 60°C)
0 to 90% rel.
48 V AC/DC
1 A
30 W/60 VA
LED (red “on” when active)
IP 52
IP 65
EMC dir. 89/336/EEC
*standard settings