4
5
Error display
6
Reset
7
Technical data
8
EC Declaration of Conformity
9
Contact
Manufacturer:
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen
Following directives have been observed:
RoHS 2011/65/EU, RED 2014/53/EU
Product variants:
ProLoop Lite 1.x, ProLoop Lite 2.x
Bircher Reglomat AG
Wiesengasse 20
CH-8222 Beringen
www.bircher-reglomat.com
When an error occurs, the operating mode “A” and the error display “E” are shown alternatingly.
The LED changes to flashing red.
Mode
2 seconds
Reset 1 (recalibration)
The loop(s) is/are recalibrated.
Power supply
voltage/
power consumption
24 VDC
24 VDC -10% to +20%,
max. 1.5 W
230 VAC
230 VAC ± 10%, 50 Hz,
max. 2.9 VA
Loop inductiveness Max. 20 to 1000 µH
Ideally 80 to 300 µH
Loop power line
For 20-40 µH: max. 100 m with 1.5 mm
2
For >40 µH max. 200 m with 1.5 mm
2
Min. twisting 20 times per metre
Loop resistance
< 8 ohms with connection wire
Output relay (loop)
Max. 240 VAC; 2 A / 30 VDC; 1 A; AC-1
Dimensions
22.5 x 92 x 85 mm (W x H x D)
Housing mounting
Direct DIN rail mounting
Connection type
Screw-in terminals
Protection class
IP 20
Operating
temperature
-20°C to +60°C
Storage
temperature
-40°C to +70°C
Air humidity
< 95% non-condensing