2
UV-lamp replacement
After approximately one year of continuous use (2-3 years if the device is used
occasionally) the power of the UV lamp decreases and it needs to be replaced.
You also get an indication when the light under the word "POWER" starts to
turn red.
Set the control to "Off" and disconnect the unit.
Make sure the lamp is cold
Unscrew the back piece to reach the lamp.
Remove the clips that hold the lamp. These you do not need to put back. (They
are only ment to secure the original transportation from the factory.)
Carefully remove the lamp by pulling the lamp out of the socket.
Insert the new lamp without touching the glass with your fingers. (use only
BioZone original lamps, the use of another lamp will void the warranty)
Replace the back cover, plug in and start the device. Make sure the UV light is
on (blue or green light).
Now you can reset time calculator by pressing one end of a clip or a needle for
10 seconds in the small hole under the word "RESET". You must press until the
lamp under "POWER" lights up and you can hear a click.
If you want to clean the fan, it is usually enough to spray with a standard
compressed air spray.
NOTE! Hazardous waste! The lamp is thrown in containers intended for
lamps containing mercury.
Unit
Lamp #
BZ-PR45/05
lamp # 10-08010
BZ -PR90/10
lamp # 10-08025
BZ-PR180/20
lamp # 10-08050
BZ-PR270/30
lamp # 10-08100
Operating Costs
BioZone's devices include advanced electronics with its own unique
power supply that ensures that the UV lamp can keep the wavelengths
required for optimal air purification. BioZone uses 12V, making it safe to
use.
BioZone air cleaner requires almost no maintenance (except for lamp
replacements) and is easy to handle and cheap to own. The power
consumtion is less than 15W.