UV-lamp replacement 

After approximately one year of continuous use (2-3 years if the device is used 
occasionally) the power of the UV lamp decreases and it needs to be replaced. 
You also get an indication when the light under the word "POWER" starts to 
turn red. 
Set the control to "Off" and disconnect the unit. 
Make sure the lamp is cold 
Unscrew the back piece to reach the lamp. 
Remove the clips that hold the lamp. These you do not need to put back. (They 
are only ment to secure the original transportation from the factory.) 
Carefully remove the lamp by pulling the lamp out of the socket. 
Insert the new lamp without touching the glass with your fingers. (use only 
BioZone original lamps, the use of another lamp will void the warranty) 
Replace the back cover, plug in and start the device. Make sure the UV light is 
on (blue or green light). 
Now you can reset time calculator by pressing one end of a clip or a needle for 
10 seconds in the small hole under the word "RESET". You must press until the 
lamp under "POWER" lights up and you can hear a click. 
If you want to clean the fan, it is usually enough to spray with a standard 
compressed air spray. 

NOTE! Hazardous waste! The lamp is thrown in containers intended for 
lamps containing mercury. 

 

Unit

 

 Lamp # 

 
BZ-PR45/05  

 lamp # 10-08010

  

BZ -PR90/10

 

 lamp # 10-08025

  

BZ-PR180/20

 

 lamp # 10-08050

  

BZ-PR270/30

 lamp # 10-08100

  

Operating Costs 

BioZone's devices include advanced electronics with its own unique 
power supply that ensures that the UV lamp can keep the wavelengths 
required for optimal air purification. BioZone uses 12V, making it safe to 
use. 
BioZone air cleaner requires almost no maintenance (except for lamp 
replacements) and is easy to handle and cheap to own. The power 
consumtion is less than 15W. 