12
– mark the boiler with the plate "FAULTY – DO NOT SWITCH ON";
– report to the management of the enterprise about the failure;
– ascertain the reason of the failure;
– if it is the simple failure, it can be eliminated on your own using technical services or
technical department of the enterprise. This
Operation Manual includes the list of such
failures
.
CAUTION!
Intervention in such systems as: electrical, electronic and
mechanical is unallowable.
– If it is the serious breakdown, contact an authorized service center or use the
damage claim and contact the burner manufacturer.
4. TECHNICAL MAINTENANCE
4.1. General Instructions
Throughout the entire lifecycle of the boiler and the burner the user shall perform
routine cleaning as well as periodic inspections, and preservation of all units. They
also
include periodic annual checks of chimneys
.
4.2. Safety Measures
Basic principles and recommendations to follow while operating the boiler with the
burner «AIR PELLET
60
KW
»:
– Individuals who got familiar with the Operation Manuals for the boiler, the burner,
and the controller as well as with all possible threats can be allowed to operate this system
.
CAUTION!
Requirements as to hookup and operation of the boiler are
described in the technical documentation.
–
It is prohibited to use the burner with a faulty seal of the mounting plate.
In case of
smelling carbon monoxide from the outside of the boiler it is required to immediately turn off
the burner and restore the tightness of the seal.
– If it is necessary to carry out work inside the boiler, always turn off the burner and
wait for about 20 minutes to ventilate and cool off the combustion chamber.
– While performing a control (visual) test of the burner operation that might require
even a brief inspection of the combustion chamber, when opening the door one shall always
stand on the side of the door so as not to get a burn of the face an
d body with hot air. Do not
open the furnace doors with the burner installed!
– Do not touch the burner during its operation
.
Touching hot elements of the burner
with bare hands might result in the burn!
– When cleaning, always use protective gloves
.
Caution! To perform this work one
should not use the tools that could damage the equipment installed in the ejector tube of the
burner (grates,
ignition system, etc.).
CAUTION!
During the boiler and the burner operation, it is strictly forbidden to
drop hands into the elements of the screw feeder and the bunker with the fuel. This
might result in severe damage to the hands.
– Do not touch electrical wires or live electrical equipment
.
In case of such necessity,
it is always required to switch off the power supply to the whole system (boiler-burner-screw