Electrocardiograph (Ver 1.0)

12

How to Set BCM-600

How to Set BCM-600  

13

BCM-600

How to Set BCM-600

(3)  Maintenance and Cleaning After Use

A. Keep the product cleans by cleaning it using a soft cloth at least once a month. Do not use

thinner, ethylene, oxidant or lacquer since these may damage the product.

B. Keep the accessories clean of dust or foreign materials. For cleaning, use a soft cloth and

clinical alcohol.

C. Do not soak the accessories in liquid or detergents. Keep the product and accessories out of

any liquid.

D. For the protection of the environment, please contact the agency you purchased the product

from when you wish to discard the BCM-600

E. Our product can be used semipermanently.  Please contact our Customer Service dept. or any

distributor and then replace the parts , when  wasting parts such as battery, LCD or LED and

so on have a problem .

(1)  Precautions for Settings

Pay attention when setting BCM-600 for the following points

- Use BCM-600 under conditions of 10

℃∼

45

of circumstantial temperature and 30

%∼

85

humidity.

- Check the connection status of the power cord.

- Do not connect multiple cords to the power supply.

- Place the main body on a flat area.

- If noise occurs, ground the equipment.

- Do not use any electric cords generating connecting noise.

- Take care since the product can be broken by mechanical shock.

- Get rid of dust or inflammable material near the product when setting it up.

(2)  Checkpoints before Use

Check the following points before measuring the patient’s condition. 

- Make sure there is no mechanical risk.

- Check the lead, power plug, and accessories connected on the outside.

Precautions Before Use

Do not use product near dynamo, X-ray equipment, broadcast equipment.

Do not twist the cable.

Attach each Lead properly.

Keep the patient motionless with comfortable position while measuring

Содержание BCM-600

Страница 1: ...82 33 434 9041 Fax 82 33 434 9043 Seoul Office R D 1406 Masters Tower 553 Dohwa dong Mapo gu Seoul Korea zip 121 748 Tel 82 2 714 2960 2 Fax 82 2 714 2963 Customer Service Dept Tel 82 2 714 2962 Fax 8...

Страница 2: ...OPERATION MANUAL BCM 600 Electrocardiograph Ver 1 0 OCT 26 2010...

Страница 3: ...M 600 10 8 Composition of BCM 600 11 9 How to set BCM 600 12 Precations for Settings 12 Checkpoints Before Use 12 Maintenance and Cleaning After Use 13 10 Components of BCM 600 14 Front Operation Pane...

Страница 4: ...t that is not specified in the manual please be sure to notify our company or an agency authorized to distribute our products For various services and product information please feel free to contact o...

Страница 5: ...nt all kinds of service related responsibilities of the product sellers for the product they sell The product was manufactured under strict quality controls and the inspection process of the company T...

Страница 6: ...ipment Make sure to prevent dust especially metal debris from penetrating in Avoid damp locations and do not operate the equipment with wet hands Locations where the temperature fluctuation is rather...

Страница 7: ...d 24 months should be replaced When the product has been moved make sure to turn it off and arrange the accessories in order Injured cords or cables may cause fire or electric shock Precautions for El...

Страница 8: ...it prints in 4inch sized paper Also it can be easily used for an emergency or transport situation by built in battery and portable weight Features 12 channel ECG waves are configurated with 3channels...

Страница 9: ...uch as battery LCD or LED and so on have a problem 1 Precautions for Settings Pay attention when setting BCM 600 for the following points Use BCM 600 under conditions of 10 45 of circumstantial temper...

Страница 10: ...n 1 AC Power Button 2 Screen Shift Button 3 FREEZE Button 4 GAIN Button 5 PRINT START Button 6 SPEED Button 7 EXIT Button 8 MENU Button 9 LCD SCREEN 10 PAPER LOCK 11 PAPER Cover 12 AC Power LED 13 DC...

Страница 11: ...nting and so on Refer the following page Table 1 Explanation of Screen Icons Time Display the present time HR Display the Heart Rate of a Patient Fig1 Main Screen Symbol Comments Symbol Description Ty...

Страница 12: ...rmal Green Abnormal Red Normal Green Abnormal Red Flickers at 1 second interval Flickers at 1 second interval Flickers at 1 second interval Fixed Fixed How to Use BCM 600 1 How to Use Step 1 Turn on t...

Страница 13: ...ft the menu button and press 1 EKG setting MENU MENU PRINT PATIENT SETUP EXIT MENU MENU PRINT PATIENT SETUP EXIT EKG LEAD SPEED GAIN FILTER MUSCLE BASELINE NOTCH Return Electrocardiograph Ver 1 0 20 M...

Страница 14: ...s set NOTCH MONITOR DIAGNOSIS FREEZE MONITOR Patient s information WAVE display DIAGNOSIS Patient s information WAVE Diagnosis information FREEZE Patient s information WAVE output Changeable Range Des...

Страница 15: ...TE TIME Initialize LANGUAGE Within 16 characters Year Month Day Hour Min OFF ON English Hospital name setting Date time setting Initialization Default Set referrence DEMO MODE setting Language Select...

Страница 16: ...makes users to get more accurate judgments In order to change the print processing speed size and cannel setting press the Menu button to EKG menu where you can change the setting value If you use an...

Страница 17: ...2 In order to change the print properties press the Menu button after moving to that properties by rolling the Menu button to right or left 3 To print select Print Menu And to move to no 1 select CANC...

Страница 18: ...00 times 100 Charge discharge 50 Charge discharge 30 Charge discharge Power Battery Specifications During operation using AC power noise may occur in the waveform If this is the case ground the produc...

Страница 19: ...B Electrode Attachment Check the status of the electrode attachment When you measure a patient s condition Make sure if there are mechanical hazards or not Check the cable connected to External and a...

Страница 20: ...ble 3 Check if the product is grounded The power of the product is not turned off The waveform is not normal The power of the product turns off suddenly during use The power of the product is not turn...

Страница 21: ...re Polarization voltage 350mV min Time constancy 3 2 seconds 0 20 Sensitivity 5 10 15 mm mV 5 Frequency response 0 05 100Hz 13dB Filters AC50 60 Hz 20dB or lower Muscle tremor 35 to 45 Hz 3db 6db oct...

Страница 22: ...medical device Only the products that have Passed our extensive and thorough quality tests are offered to our customers Our policies on repairing exchange and refund complies with Regulation on Consu...

Отзывы: