PROGRAMMABLE TIMER
The Galileo
®
Wireless Air Quality Center has a programmable
timer feature. You can program the air cleaner to turn on and
off at your convenience.
NOTE:
The Galileo
®
Wireless Air
Quality Center must be used to turn the air cleaner on, set the
operating speed and turn air cleaner off in order for the timer
to work (Steps 1-3 below).
1. Using the Galileo
®
Wireless Air Quality Center turn the air
cleaner on by pressing the “ON/OFF” button.
(see Operating Instructions on page 7 for more details)
2. Set the desired operating speed by using the “MODE” button.
3. Then using the Galileo
®
Wireless Air Quality Center turn the
air cleaner off by pressing the “ON/OFF” button.
4. To program the timer press the “TIMER” and “SET” buttons
at the same time
a) Set the “Timer On” time first: To set the time the air
cleaner will come on, press the “TIMER” and “SET”
buttons at the same time. The hour numbers in the
timer section will begin to flash.
b) Press “+” or “-” to set desired hour, then press “SET”.
c) When a button has not been pressed for a few seconds
OR when the “SET” button is pressed again, the minute
numbers will begin to flash.
d) Press the “+” and “-” to adjust the minutes as indicated
above in step 2.
e) When a button has not been pressed for a few seconds
OR when the “SET” button is pushed again, the timer
“ON” will be set and the Timer “OFF” will begin flashing.
f) Set the “Timer Off” time second by following instructions
in step 4a-e.
5. After completing timer set operation, the “TIMER ON” and
programmed time will be displayed.
6. Once the unit has begun operating in timer mode, the
“TIMER OFF” and programmed off-time will appear in the
top display.
7. To turn off the programmable timer, press and hold the
“TIMER” button for 3 seconds.
NOTE:
If the air cleaner is turned on before timer mode
begins, the unit will remain on and “TIMER OFF” will appear
on the display. The air cleaner will still turn off as programmed.
GALILEO
®
WIRELESS AIR QUALITY CENTER
The Galileo
®
Wireless Air Quality Center serves as a command
center for the air cleaner. It remotely operates the air cleaner by
sending continuous signals from the Galileo
®
Wireless Air Quality
Center to the air cleaner. This one way communication can be
overridden by operating the controls directly on the air cleaner.
When using the Galileo
®
Wireless Air Quality Center, the yellow
LED marked "AUTO" on the air cleaner will illuminate. When
10
water (not dishwasher safe). Dry before replacing in the unit.
3. The front air outlet grill can be cleaned of dust with a small
soft brush or cloth.
WARNING:
Do not allow moisture to come in contact with
the main housing of the air cleaner.
PERMATECH™ FILTER CLEANING INSTRUCTIONS
1. Turn off and unplug the unit before cleaning.
2. Filter Service Indicator – Your air purifier has an indicator
light that illuminates when it is time to clean the
PERMAtech™ filters.
3. Every few weeks, check the condition of the filters.
4. Remove the air inlet grill by pulling the air inlet grill towards
you by grasping the finger tabs on both sides.
5. Remove and examine the foam pre-filter. If it has collected a
noticeable amount of dust or lint, remove it from the inlet of the
grill and wash it in warm soapy water. Rinse and drip dry the
pre-filter thoroughly before replacing it into the inlet of the grill.
6. With the rear grill removed, check the condition of your
PERMAtech™ filters. If the filters are dirty, remove them by
gripping on both sides and pulling forward.
7. To clean the PERMAtech™ filter use a crevice tool or brush
attachment with your vacuum cleaner. Run the attachment
along the inlet and outlet side of the filter trying to clean
between the pleated filter layers. (Figure 4).
DO NOT USE WATER OR ANY OTHER HOUSEHOLD
CLEANERS OR DETERGENTS TO CLEAN THE
PERMAtech™
FIL
TER.
NOTE: Vacuuming will restore
performance of the PERMAtech™
filter however, the filter may appear
stained. This is normal and does
not affect performance in any way.
8. This model utilizes a hang tab and
filter clips to insure that the filter is
properly in place. Before replacing
the PERMAtech™ filter make sure
that the hang tab is securely in place.
The clip can only be attached to the
tabs on the filter one way. The filter
clip should easily slide onto the filter
hang tab with only a small amount of
pressure. DO NOT use force while
attaching the clip to the filter. (Figure 5).
9. Align the clip on the top of the
PERMAtech™ filter with the rails on
the inside of the purifier unit. Gently
slide the filter onto the rail (Figure 6).
NOTE:
The side with the soft gas
ket should face inward.
Figure 4
Figure 5
Figure 6