4. Put the filter back in the filter supports, replace the housing, then refill

the tank with cool tap water as instructed in filling the water tank

instructions.

WEEKLY MAINTENANCE

Remove scale:

1. Repeat steps 1-3 above.

2. Clean the base by partially filling the base with one 8-oz 

cup of undiluted white vinegar, or by using Clean-Away™ 

by Bionaire

®

. Let solution stand 20 minutes, clean all interior 

surfaces with a soft brush. 

3. Dampen a cloth with undiluted white vinegar and wipe out 

entire base to remove scale.

4. Rinse with clean warm water to remove scale and the white 

vinegar solution before beginning to disinfect the tank.

Disinfect Tank:

1. Fill tank with 1/2 teaspoon of chlorine bleach 

and 1/2 gallon of water.

2. Let the solution stand for 20 minutes, swishing every 

few minutes.  Wet all surfaces.

3. Empty the tank after 20 minutes, and rinse well with water until 

the bleach smell is gone.  Dry with a clean cloth or paper towel.

4. Refill the water tank with cool water; replace the housing 

and the water tank.  Repeat ALL Operating Instructions.

SERVICE INSTRUCTIONS

1. Do NOT attempt to repair or adjust any mechanical 

functions on this unit.  Doing so will void the warranty.  

The inside of the unit contains no user serviceable 

parts.  All servicing should be performed by qualified 

personnel only.

2. If you need to exchange the unit, please return it in its 

original carton, with a sales receipt, to the store where 

you purchased it.  If you are returning the unit more 

than 30 days after the date of purchase, please see 

the enclosed warranty.

3. Should your humidifier require service, please call 

1-800-788-5350 

in North America for further assistance.

4. If you have any other questions or comments,

feel free to write to us:

P.O. Box 400
Milford, MA 01757
USA

8

papier. (NE P

AS utiliser des dispositifs de nettoyage métalliques ni des net-

toyants abrasifs.)

4.

Réinsérez le filtr

e dans les supports de filtre, r

epositionnez le boîtier 

et remplissez le réservoir avec de l’eau fraîche, tel qu’indiqué à la section

«Remplissage du réservoir d’eau

». 

ENTRETIEN HEBDOMADAIRE

Enlèvement du tartre:

1.

Répétez les étapes 1 à 3 ci-dessus.

2.

Nettoyez la base en y versant une tasse de 8 oz (250 ml) de vinaigre blanc

non dilué ou la solution

Clean-Away

MC

de Bionaire

®

Laissez la solution

dans la base pendant 20 minutes et nettoyez ensuite toutes les surfaces

internes à l’aide d’une br

osse à poils doux. 

3.

À l’aide d’un chiffon humecté de vinaigr

e blanc non dilué, essuyez la base

pour enlever le tartre.

4.

Rincez à l’eau propr

e et chaude pour enlever le tartre et la solution 

de vinaigre blanc avant de commencer la désinfection du réservoir

.

Désinfection du réservoir:

1.

Versez 1/2 gallon (2 litr

es) d’eau dans le réservoir et ajoutez 1/2 cuillère 

à thé d’eau de javel.

2.

Laissez la solution travailler dans le réservoir pendant 20 minutes en la

remuant toutes les quelques minutes. Assur

ez-vous que toutes les surfaces

sont mouillées. 

3.

Vidangez le réservoir après 20 minutes et rincez-le à l’eau jusqu’à ce que

l’odeur d’eau de Javel ait disparu. Essuyez les surfaces avec un chiffon 

propr

e ou un essuie-tout en papier. 

4.

Remplissez le réservoir d’eau avec de l’eau fraîche. Repositionnez le boîtier

et le réservoir d’eau. Répétez les instructions d’utilisation.

DIRECTIVES POUR LE SERVICE APRÈS-VENTE 

1.NE tentez P

AS de réparer ou d’ajuster les fonctions électriques 

ou mécaniques de cet appareil puisque cela annulera la garantie. 

2.Si vous avez des questions concer

nant le fonctionnement de cet

appareil ou si vous cr

oyez qu’il doit être réparé, veuillez composer 

le 1-800-253-2764 et communiquer avec un représentant du 

service à la clientèle. 

3.Si vous devez r

emplacer l’appareil, veuillez le r

etourner

, emballé dans

la boîte d’origine et accompagné du reçu de caisse, au magasin où

vous l’avez acheté. Si vous devez retour

ner l’appareil plus de 30

jours après la date d’achat, veuillez consulter la garantie ci-jointe. 

4.Si vous avez d’autr

es questions ou commentaires, n’hésitez pas 

à nous écrire

P .O. Box 400

Milford, MA

01757

USA

8

Содержание COOL MOISTURE BCM1850

Страница 1: ...ns before operating Retain for future reference Instruction Leaflet INFO LINE If after having read this leaflet you have any questions or comments on your humidifier call 1 800 788 5350 in North America hu Veuillez lire les di Fic Si après avoir lu l à formul ...

Страница 2: ...njury Be sure to pull the plug and not the cord 7 Never place anything over moisture outlet when the unit is running 8 NEVER drop or insert any object into any openings 9 DO NOT operate any appliance with a damaged cord or plug after the appliance malfunctions or if it has been dropped or damaged in any manner Return appliance to manufacturer for examination electrical or mechanical adjustment or ...

Страница 3: ...he inside of the unit contains no user serviceable parts All should be performed by qualified personnel only 21 Never place housing under water flow or immerse in liquids 22 Do not plug in the cord with wet hands electric shock could result 23 Do not pour water in any openings other than the water tank 24 To prevent damage to surfaces do not place humidifier under overhanging surfaces PLEASE SAVE ...

Страница 4: ...ool invisible moisture output It is normal not to see the mist NOTE A humidity level below 20 can be unhealthy and uncomfortable The recommended humidity level is between 40 50 PRE OPERATING INSTRUCTIONS 1 Push the 1 Touch button for 2 seconds to turn the unit OFF and disconnect from the electrical outlet 2 Select a location for your humidifier on a flat surface about 4 away from the wall Do not p...

Страница 5: ... Plug the power cord into a 120V AC electrical outlet OPERATING INSTRUCTIONS Your humidifier is equipped with a technologically advanced 1 Touch Electronic Humidistat You can set the humidifier to run continuously in manual mode or set the 1 Touch Electronic Humidistat to your desired temperature setting The 1 Touch Electronic Humidistat will automatically turn the humidifier ON or OFF depending o...

Страница 6: ... the more often you will need to change your filter You will be able to monitor the life of the filter in your humidifier by checking the Filter Check Indicator When the unit is off the Filter Check Indicator will read in the OFF position After 60 minutes of use Filter Check Indicator refer to Figure 3 for close up of indicator will move from the OFF position and indicate your filter condition A b...

Страница 7: ...You can purchase replacement filters Model BWF65 by calling 1 800 788 5350 or by visiting www bionaire com Please refer to the Replacement Accessories section at the end of this manual for the appropriate filter and solutions for this humidifier It is recommended that a replacement filter is purchased for uninterrupted use STORAGE NSTRUCTIONS If your humidifier will not be in use for two days or m...

Страница 8: ... and the water tank Repeat ALL Operating Instructions SERVICE INSTRUCTIONS 1 Do NOT attempt to repair or adjust any mechanical functions on this unit Doing so will void the warranty The inside of the unit contains no user serviceable parts All servicing should be performed by qualified personnel only 2 If you need to exchange the unit please return it in its original carton with a sales receipt to...

Страница 9: ... any personal injury property or any incidental or consequential damages of any kind including water damage resulting from malfunctions defects misuse improper installation or alteration of this product All parts of this Bionaire product are guaranteed for a period of 6 years as follows 1 Within the first 30 days from date of purchase the store from which you purchased your Bionaire product should...

Страница 10: ...our wick filter BWF65 by calling 1 800 788 5350 or visit www bionaire com Use Clean Away Solution DMS216 to order call 1 800 788 5350 or visit www bionaire com Replace your wick filter BWF65 by calling 1 800 788 5350 or visit www bionaire com Refill using cool water Set the humidistat to a higher or lower setting Add liquid soap or pertroeum jelly to cap gasket to ease opening ur Solution angez l ...

Отзывы: