Commissioning
1. Wiring non-dimmable power supply ND series
+36 VDC power supply connect to wire 1 (marked blue), wire 2, wire 4, wire 5 of the leader cable
GND power supply connect to wire 3 and wire 6 of the leader cable
Before commencing any installation or maintenance work, please disconnect the power supply from the utility.
Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
Ensure that it cannot be re-connected inadvertently!
Keep proper ventilation around the unit and do not stack any object on it.
Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal
component temperature and will result in a derating of output current.
Dont suspend to direct sunlight or rain
Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its
specification.
For LED power supplies with waterproof connectors, verify that the linkage between the unit and the lightingfixture is tight so that
water cannot intrude into the system.