Dashboard Warnings

When you log in, you will be presented with a dashboard 
with a list showing the status of all BG-Counters in your ac-
count.  Any devices with warning status are displayed on top 
of the list. The following warnings are indicated with a red 
triangle:

Fan column:

 A triangle here means one of two conditions have been 

detected:
1.) The fan current is low, indicating the fan is not running 
even though it is turned on
2.) The fan current is high, indicating a stall (i.e. something is 
blocking the fan blades)
Corrective action:  Check the fan for proper operation.

Voltage Column

:

The low and high supply voltage for the last 24 hours are 
displayed.

 A triangle here means that the lowest voltage is less than 

11.5V, indicating a discharged battery or a solar system that 

is not charging properly.  The counter will be turned off when 

the voltage drops to less than 11.2V in order to protect the 

electronics.  Once turned off, the counter remains turned off 

until the voltage builds up again to 11.8V.
Corrective action may include one or more of the following:
•  Charge the battery
•  Use a battery with higher capacity
•  Make sure solar panels are in full sun
•  Check connections on solar controller
•  Check solar controller for proper function
    

You can choose to be notified with an e-mail if warnings are 
present.    In  order  to  turn  on  Notifications,  click  on  Profile, 

then click on Notify me about warnings and click Save.

Trap does not start up

Symptoms: 

•  No beeps after connecting power
•  Fan not working
•  CO

2

 valve not clicking

•  A blue glow may be visible when looking into the counter 

funnel

Cause: 

 

No power or wrong polarity

Solution:

 Check voltage, continuity, and polarity on the po-

wer connection.

Only one or two beeps upon start-up

Symptoms: 

 Counter, fan and CO

2

  valve  are  off.    No  data 

transmission.

Cause:

 Battery is too low.

Solution: 

Recharge battery, or replace with full battery.

SOS beep during start-up

Symptom: 

3 short, 3 long, 3 short beeps

Cause: 

SD card failure

Solution: 

Contact support

Checking cellular connectivity

If the counter is in a location with weak cellular signal, the 

cellular data connection to the server may be unreliable. 
The signal strength at the deployment site can be checked 
as follows:

Connect counter to power, then listen for beeps
1.) Immediately:

  One to four beeps indicating battery vol-

tage
4 beeps: fully charged
3 beeps: partially charged
2 or 1 beep: discharged, counter and trap will not run

2.) After 10-90 seconds

, 1-5 long beeps indicating cellular 

signal strength (like the bars on a cell phone)
3-5 beeps: strong signal
2 beeps: marginal signal
1 beep: weak signal
Two short beeps: no connection

Cellular signal too low

Symptoms:

 Two short beeps about 1-2 minutes after con-

necting the trap to power.

Cause: 

Weak or no cellular reception at the present location 

of trap.

Solutions:

 

 

•  Move trap to a location which has stronger reception
•  Continue using the trap: data will be saved and uploaded 

upon the next time there is reception

• 

If the cellular signal is very small in a remote location, the 

following antennas may provide improvement

.  They can 

be ordered directly from the suppliers listed.

1.)  Advantech AO-AGSM-MG9S

Magnetic Mount

Includes 3.5m cable with SMA connector (directly fits BG-

Counter antenna connection)
https://www.mouser.com/ProductDetail/Advantech/AO-
AGSM-MG9S?qs=sGAEpiMZZMuBTKBKvsBmlN73K%2F2B

cYXlxNBf4MnSdn03UqYJSeMj4A%3D%3D

2.) Taoglas OMB.8912.03F21

Wall/Pole Mount
Female N-type connector
https://www.mouser.com/ProductDetail/Taoglas/OMB89

1203F21?qs=sGAEpiMZZMuBTKBKvsBmlIvfvst9g9R40Frl

fwg%252BLe8sulGjmpHLMA%3D%3D
Requires separate adapter cable (N-type plug to SMA 
male), to be ordered in the needed length, for example:
https://www.amazon.com/Low-Loss-Extension-

Co n n e c t o r - G E M E K - A r re s t e r /d p / B 0 7 P 1 2 X W 3 J /

ref=sr_1_4?keywords=n-type+to+sma+cable&qid=1562
655621&s=gateway&sr=8-4

Troubleshooting

Содержание BG-Counter

Страница 1: ...Updates for the manual can be found on the website www bg counter com Status July 2020 BG CounterTM Instruction Manual...

Страница 2: ...o Power 3 Options Determination of Counting Accuracy Operating the BG Counter First Cloud Connection Reset Maintenance BG Counter Webseite Description Registration at live bg counter com Dashboard Mai...

Страница 3: ...he BG Pro with a spe cial 12 V fan or a BG Sentinel trap that remove the insects after they are sucked through to avoid multiple counts of the same insect To ensure accurate counts the trap must not a...

Страница 4: ...djustable regulator 1 9 Battery adapter cable 1 10 AC power cord with transformer 1 11 BG Counter fan 3 blade 12 V 2 Solar system 2 1 Solar panel with connectors 2 2 Solar controller with connectors 2...

Страница 5: ...until it fits tight F2 Then follow assembly instructions for the BG Pro See manual at www biogents com but do not place the fun nel into the opening on top of the cover F3 The BG Counter will be place...

Страница 6: ...and also fix them with nuts F5 3 Set up the BG Pro in the stand Insert an enclosed screw through one of the holes on the central upper bracket of the BG Pro Continue to insert the screw through one of...

Страница 7: ...on about this topic see chapter De termination of Counting Accuracy 5 Fix the antenna on the BG Counter Place the BG Coun ter on a flat surface with the antenna connector facing up see Fig F10 Screw o...

Страница 8: ...k and make sure it is tight by using a wrench or pliers F14 2 Connect the free end of the CO2 tubing to the regulator F15 unscrew the nut on the outlet thread the end of the CO2 tube through the nut i...

Страница 9: ...ottom of the trap However a catch bag can be installed when the BG Counter runs only for a few hours in order to check if the number of counted mosquitoes by the BG Counter corresponds with the actual...

Страница 10: ...16 15 This provides time for the ope rator to confirm that the BG Pro 12 V fan is indeed working and the CO2 flow is on Confirm fan operation visually by looking into the trap fun nel or by holding a...

Страница 11: ...ter enter your e mail address re enter your e mail address to make sure it s correct enter the serial number of the counter IMEI located on a sticker on the bottom of the counter select from the left...

Страница 12: ...g indicate low fan current 5 or low and high supply voltage 6 More information on the dashboard warnings can be found on page 19 in the Troubleshooting section The traps are listed below the map in a...

Страница 13: ...the map or in the list below the map In Your Traps main menu left side click on a trap name In Trap Management main menu left side click on a trap name or click on View In the field Trap Day 7 you ca...

Страница 14: ...be assigned and click on Users In the Assign Trap to User screen select an operator or guest from the drop down list Click Assign Second possibility Click on Users Find the operator or guest to whom y...

Страница 15: ...th exact trap location down to the nearest bush perhaps it is possi ble to use Google Maps to set the exact location of the trap Click on the pencil icon next to Trap Location 11 Now an arrow is shown...

Страница 16: ...nter to attract mos quitoes while at the same time repelling other insects This field cannot be edited Data connection Determines how often the counter will try to connect to the website and transmit...

Страница 17: ...all on at the same time However if for example a catch bag is installed and the catch is to be retained for coll ection leave the fan on continuously Normally the schedule is set to repeat daily howev...

Страница 18: ...esented for 15 minute intervals All times are local time at the last known location of the trap Chart settings In Chart Settings you can select for display Insect Types Mosquitoes Large Objects Small...

Страница 19: ...o low Solution Recharge battery or replace with full battery SOS beep during start up Symptom 3 short 3 long 3 short beeps Cause SD card failure Solution Contact support Checking cellular connectivity...

Страница 20: ...al strength 3 5 long beeps After verifying cellular signal strength there will be about 5 additional short beeps followed by a long beep After 30 minutes go to the web site and see if there are new tr...

Страница 21: ...s 32 and are therefore also counted several times 33 Solution A Remove the funnel net and catch bag 34 B In case you need to analyze the mosquitoes install a catch bag below the fan 35 2 Cause Mosquit...

Страница 22: ...Email sales biogents com Contact Weight Body 730 g Dimension Body 23 x 23 x 14 cm BG Counter including ventilator 12V DC 7 Watt Switching power supply AC Input 100 230V Frequency 60Hz 50Hz DC Output...

Отзывы: