background image

11

EN

The web application allows you to remotely switch traps in 

the field on and off. It also allows you to set up varying time 

schedules to run the traps and to set up application times 
of attractants. Further you have access to all collected data 
including local environmental data such as temperature, hu-
midity, or light. 

BG-Counter Website Description

On the website and in these instructions, the word “trap” re-
fers to a complete system including a trap and a counter.

 

The website address is live.bg-counter.com. Any modern web 
browser (PC, tablet, or mobile phone) can be used to access 
the website.  
No registration is necessary to view the traps in the “Demo” 
account.
To take advantage of the full functionality of the website, 

you must first be registered.  

Registration for the Administrator (there is only one Admi-
nistrator  for each organization):

•  go to live.bg-counter.com and click on „Register“
•  enter your e-mail address
•  re-enter your e-mail address to make sure it’s correct
• 

enter the serial number of the counter (IMEI, located on 

a sticker on the bottom of the counter): select from the 

left hand side (1) the number that fits to the first digits 

of your serial number. Then add the last 7 digits in the 

right field.

Registration at live.bg-counter.com

You  will  receive  a  confirmation  e-mail  (please  have  also  a 

look for the e-mail in your spam folder) with a temporary 
password and a link to activate your account.
Now you are a registered Administrator.

Log-in:

To check and control the counter, go to live.bg-counter.com:

•  log-in with your e-mail address and your temporary pass-

word

• 

click on “Profile” to set a new password for your account

•  set a checkmark in the box “Notify me about warnings” 

if you want to be notified via e-mail if warnings are re

-

gistered

•  click on “Trap Management” to set the counter name, 

schedule etc

•  click on “User Management” to invite other users, such as 

operators and guests

If you have more than one counter, you can add them to your 

account in “Trap Management”.

1

Содержание BG-Counter

Страница 1: ...Updates for the manual can be found on the website www bg counter com Status July 2020 BG CounterTM Instruction Manual...

Страница 2: ...o Power 3 Options Determination of Counting Accuracy Operating the BG Counter First Cloud Connection Reset Maintenance BG Counter Webseite Description Registration at live bg counter com Dashboard Mai...

Страница 3: ...he BG Pro with a spe cial 12 V fan or a BG Sentinel trap that remove the insects after they are sucked through to avoid multiple counts of the same insect To ensure accurate counts the trap must not a...

Страница 4: ...djustable regulator 1 9 Battery adapter cable 1 10 AC power cord with transformer 1 11 BG Counter fan 3 blade 12 V 2 Solar system 2 1 Solar panel with connectors 2 2 Solar controller with connectors 2...

Страница 5: ...until it fits tight F2 Then follow assembly instructions for the BG Pro See manual at www biogents com but do not place the fun nel into the opening on top of the cover F3 The BG Counter will be place...

Страница 6: ...and also fix them with nuts F5 3 Set up the BG Pro in the stand Insert an enclosed screw through one of the holes on the central upper bracket of the BG Pro Continue to insert the screw through one of...

Страница 7: ...on about this topic see chapter De termination of Counting Accuracy 5 Fix the antenna on the BG Counter Place the BG Coun ter on a flat surface with the antenna connector facing up see Fig F10 Screw o...

Страница 8: ...k and make sure it is tight by using a wrench or pliers F14 2 Connect the free end of the CO2 tubing to the regulator F15 unscrew the nut on the outlet thread the end of the CO2 tube through the nut i...

Страница 9: ...ottom of the trap However a catch bag can be installed when the BG Counter runs only for a few hours in order to check if the number of counted mosquitoes by the BG Counter corresponds with the actual...

Страница 10: ...16 15 This provides time for the ope rator to confirm that the BG Pro 12 V fan is indeed working and the CO2 flow is on Confirm fan operation visually by looking into the trap fun nel or by holding a...

Страница 11: ...ter enter your e mail address re enter your e mail address to make sure it s correct enter the serial number of the counter IMEI located on a sticker on the bottom of the counter select from the left...

Страница 12: ...g indicate low fan current 5 or low and high supply voltage 6 More information on the dashboard warnings can be found on page 19 in the Troubleshooting section The traps are listed below the map in a...

Страница 13: ...the map or in the list below the map In Your Traps main menu left side click on a trap name In Trap Management main menu left side click on a trap name or click on View In the field Trap Day 7 you ca...

Страница 14: ...be assigned and click on Users In the Assign Trap to User screen select an operator or guest from the drop down list Click Assign Second possibility Click on Users Find the operator or guest to whom y...

Страница 15: ...th exact trap location down to the nearest bush perhaps it is possi ble to use Google Maps to set the exact location of the trap Click on the pencil icon next to Trap Location 11 Now an arrow is shown...

Страница 16: ...nter to attract mos quitoes while at the same time repelling other insects This field cannot be edited Data connection Determines how often the counter will try to connect to the website and transmit...

Страница 17: ...all on at the same time However if for example a catch bag is installed and the catch is to be retained for coll ection leave the fan on continuously Normally the schedule is set to repeat daily howev...

Страница 18: ...esented for 15 minute intervals All times are local time at the last known location of the trap Chart settings In Chart Settings you can select for display Insect Types Mosquitoes Large Objects Small...

Страница 19: ...o low Solution Recharge battery or replace with full battery SOS beep during start up Symptom 3 short 3 long 3 short beeps Cause SD card failure Solution Contact support Checking cellular connectivity...

Страница 20: ...al strength 3 5 long beeps After verifying cellular signal strength there will be about 5 additional short beeps followed by a long beep After 30 minutes go to the web site and see if there are new tr...

Страница 21: ...s 32 and are therefore also counted several times 33 Solution A Remove the funnel net and catch bag 34 B In case you need to analyze the mosquitoes install a catch bag below the fan 35 2 Cause Mosquit...

Страница 22: ...Email sales biogents com Contact Weight Body 730 g Dimension Body 23 x 23 x 14 cm BG Counter including ventilator 12V DC 7 Watt Switching power supply AC Input 100 230V Frequency 60Hz 50Hz DC Output...

Отзывы: