O CLEAR-Elite_(Anglais) - DOC016536 - Ind. A01 - 22/03/2021
Copyright BIO-UV
Marque, Modèles et Brevets déposés - Produits exclusifs
Page 43
7.
While remaining well aligned with the axis, introduce the quartz
sleeve into the reactor to its guide at the bottom of the reactor.
Wearing clean gloves, position the quartz to into the bottom of its holder
by using your finger inside the sleeve. A flashlight can help you to see
the holder through the quartz.
NB: Be careful not to release the quartz sleeve as long as it is not in its
holder, otherwise it could break or be difficult to recover.
8.
Replace tightening seals :
(Mount a new seal at each lamp replacement)
•
Apply water and soap on the seal,
•
Position the O-ring around the quartz sleeve
•
Push it fully into its housing using your nail (do not use any
tools).
9.
Position the sealing washer then mount the three screws.
10.
Put the installation back in pressure
before
the reassembly of the lamp
and
check that there is no leakage in the quartz sleeve
.
Before filling the reactor, remember to tighten the lower union.
11.
Refit
the lamp (see previous paragraph).