bintec elmeg H2 Auto Compact Series Скачать руководство пользователя страница 14

Fig. 7:

Outline drawing

3.3 Power Source

The bintec H2 Auto Compact is powered through direct current (DC).

Fig. 8: Power connector

Workplace Conditions. Main Characteristics

• Avoid moist and/or dusty locations.

• Avoid direct exposure to sunlight and any other heat sources. Do not place the device among papers, magazines

or other items that could hinder natural air circulation.

• Do not place the device near strong electromagnetic fields such as those produced by speakers, motors, etc.

• Avoid knocks and/or strong vibrations during operation, storage and transport.

• The device should be mounted in accordance with accepted after-sales practices and materials.

Warning

Power cables, telephone lines and communication cables are current-carrying. To prevent fire or injury,
make sure to connect and disconnect the cables following the instructions provided in

Connecting

on

page 9 and

Disconnecting

on page 9 before installing, handling or opening any of the device's cov-

ers.

3 Components and power supply

bintec elmeg GmbH

8

bintec H2 Auto Compact

Содержание H2 Auto Compact Series

Страница 1: ...bintec H2 Auto Compact Installation Manual Copyright bintec Dm1004 I Version 1 0 07 2020 bintec elmeg GmbH bintec elmeg GmbH Manual bintec H2 Auto Compact 1...

Страница 2: ...offers no warranty whatsoever for information contained in this manual bintec elmeg GmbH is not liable for any direct indirect collateral consequential or any other damage connected to the delivery s...

Страница 3: ...supply 4 3 1 Components 4 3 1 1 Front panel 4 3 1 2 Rear panel 6 3 2 Mounting options 6 3 2 1 Assembly Recommendations 7 3 2 2 Outline drawing 7 3 3 Power Source 8 3 3 1 Connecting the power cable to...

Страница 4: ...tes 24 A 2 2 Connecting to the device 24 A 3 Connectors 26 A 3 1 POWER connector 26 A 3 2 LAN Connector 26 A 3 3 WWAN Connector 26 A 3 4 WLAN Connector 27 A 3 5 GPS Connector 27 A 3 6 Configuration co...

Страница 5: ...B 2 WLAN specifications 33 bintec elmeg GmbH Table of Contents bintec H2 Auto Compact iii...

Страница 6: ...Table of Contents bintec elmeg GmbH iv bintec H2 Auto Compact...

Страница 7: ...A detailed description of the power supply requirements A description of the LEDs and connectors on the device Troubleshooting information 1 5 What is not in this manual This manual does not contain...

Страница 8: ...features Contact information Web http www bintec elmeg com Tel N 49 911 9673 0 Fax 49 911 688 0725 Email support bintec elmeg com 1 8 Related documentation bintec Dm704 I Configuration and Monitoring...

Страница 9: ...he bintec H2 Auto Compact router Fig 1 bintec H2 Auto Compact 2 1 1 Power supply For further information on the bintec H2 Auto Compact power supply please see Power Source on page 8 2 1 2 Hardware mon...

Страница 10: ...wer connection For further information on the power connection please see Power Source on page 8 B LAN1 or LAN2 connector for Ethernet C Conf Micro USB connector providing access to the device s local...

Страница 11: ...reen active connection Blinking data activity Yellow Registered but connection not established Red Unavailable and not registered SIM Active SIM Green SIM 1 active Yellow SIM 2 active Red SIM error No...

Страница 12: ...king Transferring data 3 1 2 Rear panel The following image shows the remaining connectors on the rear panel of the bintec H2 Auto Compact Fig 5 bintec H2 Auto Compact Rear panel The rear panel compon...

Страница 13: ...anchored the strain of the cables connected to the router could pull the router out Note Mounting screws are not provided with the router and must be purchased separately Note Do not mount the router...

Страница 14: ...gnetic fields such as those produced by speakers motors etc Avoid knocks and or strong vibrations during operation storage and transport The device should be mounted in accordance with accepted after...

Страница 15: ...ended installing an approved vehicle circuit breaker Insert the new fuse into the fuse box s fuse slot Connect the positive battery cable to the vehicle s battery post Fig 9 Cable Connection to vehicl...

Страница 16: ...in the bintec H2 Auto Compact is always ON In this operating mode the device expects to be constantly powered and the ACC IGNITION signal operates as a switch When power is applied to the device BATTE...

Страница 17: ...and Monit oring Note The Power Management feature is always enabled In order to disable the Power Management feature connect the IGNITION signal to the VCC BAT TERY For further information see Connect...

Страница 18: ...t from the one shown above 3 5 Connecting the data The bintec H2 Auto Compact router has the following data connections 3 5 1 2 port Ethernet Switch The bintec H2 Auto Compact incorporates a 2 port 10...

Страница 19: ...ested with antenna gain 2dBi to evaluate its conformity with CE Radio standards Only the antennas with a gain lesser or equal to 5dBi for 2 4GHz 7dBi for 5 15 5 35GHz 5 47 5725GHz and 10dBi for 5 725...

Страница 20: ...ories that allow bintec H2 Auto Compact routers to be installed at differ ent locations Note Antennas must not be directly connected to the bintec H2 Auto Compact router They should be at least 50 cm...

Страница 21: ...ecommended Use an ex tension cable and place the antenna outside The following recommendations are applicable to all wireless devices Do not touch or move the antenna while the device is transmitting...

Страница 22: ...o operate In installations where only one SIM card is required we recommend to use SIM 1 tray for SIM card installation For further information about SIM configuration please see the following manual...

Страница 23: ...slides out of the slot 2 Place the SIM card on the tray Make sure that the SIM card is properly inserted in its tray 3 Slide the tray into the slot by pushing it in Fig 17 Inserting SIM 1 SIM tray 2 1...

Страница 24: ...Finally screw the protective cover back in place Fig 18 Inserting SIM 2 3 Components and power supply bintec elmeg GmbH 18 bintec H2 Auto Compact...

Страница 25: ...tures up to 70 C 158 F Under these conditions the metal surface can reach dangerously high temperatures that may cause injuries Advertencia Este equipo ha sido dise ado para funcionar con una temperat...

Страница 26: ...IM card Always disconnect the device before removing the casing to access the trays When inserting a SIM card please protect yourself against electrostatic discharge ESD Do not touch the SIM card conn...

Страница 27: ...the data on page 12 beschrieben Warning The spaces and cavities in the vehicle secured through locks keys tools or other means only accessible to trained personnel are considered Restricted Ac cess Lo...

Страница 28: ...bH declares that the bintec H2 Auto Compact radio equipment is in compliance with Directive 2014 53 EU Directives 2011 65 EU and 2015 863 EU RoHS Spanish ES Por la presente bintec elmeg GmbH declara q...

Страница 29: ...ey comply with local regulations Please be aware of the regulations in the country where the equipment will be installed and ensure the characterist ics of the antennas are in compliance with those re...

Страница 30: ...tware updates bintec H2 Auto Compact routers can be updated to newer versions Please contact your dealer for information about new versions Our routers can be updated in several ways For further infor...

Страница 31: ...ion A 2 2 2 Configuration using the IP terminal LAN connector The bintec H2 Auto Compact has a default configuration that activates if the device has not been configured in ad vance The router default...

Страница 32: ...guring your device refer to the user manuals provided by bintec elmeg GmbH on the documentation CD or website A 3 Connectors A 3 1 POWER connector MOLEX 2x2 PIN SIGNAL 1 2 3 4 GND VCC IGNITION Input D...

Страница 33: ...FME male GPS connector installed RF FME Male PIN ANT Internal External RF In GND A 3 6 Configuration connector A Micro USB type B female configuration connector is installed Micro USB type B PIN Signa...

Страница 34: ...Cat 4 FDD 150Mbps 50Mbps TDD 130Mbps 35Mbps HSPA Cat 24 6 42Mbps 5 76Mbps EDGE 236Kbps CONNECTOR Up to two SMA female connectors SIM Slots 2 Mini SIM 2FF ISO IEC 7810 2003 ID 000 1 8V 3V General VSWR...

Страница 35: ...0ns 20 MHz MSC0 7 2 Mbps MSC1 14 4 Mbps MCS2 21 7 Mbps MCS3 28 9 Mbps MCS4 43 3 Mbps MSC5 57 8 Mbps MCS6 121 5 Mbps MCS7 135 Mbps Data rates for 802 11n Long Guard 800ns 40 MHz MSC0 13 5 Mbps MSC1 27...

Страница 36: ...eous tracking CONNECTOR RF FME male ANTENNA 3 V Active Passive General Frequency range 1559MHz 1609MHz Polarization RHCP or linear VSWR 2 Typ Antenna Requirements Passive antenna gain 0dBi Active ante...

Страница 37: ...ice A USB compatible driver must run on the connected device PC or other A 4 7 Power INPUT VOLTAGE Maximum input range 9 36 V DC Nominal 12 24 V DC INPUT CURRENT 2 A 12 V DC MAXIMUM POWER With a WWAN...

Страница 38: ...ge 40 C to 80 C 40 F to 176 F Note On negative environmental temperatures the starting time of the device increases by about 30 seconds HUMIDITY Operating 5 to 95 relative humidity non condensing Stor...

Страница 39: ...ransmit Power Band 1 Tx 1920 1980 MHz Rx 2110 2170 MHz 23 dBm 2 dB Band 3 Tx 1710 1785 MHz Rx 1805 1880 MHz 23 dBm 2 dB Band 7 Tx 2500 2570 MHz Rx 2620 2690 MHz 23 dBm 2 dB Band 20 Tx 832 862 MHz Rx 7...

Страница 40: ...z 5510 5670 MHz Number of Channels 2 4 GHz 802 11b g n HT20 13 802 11n HT40 9 5 GHz 802 11a n HT20 19 802 11n HT40 9 Type of modulation 2 4 GHz 802 11b DSSS 802 11g n OFDM 5 GHz 802 11a n OFDM Conduct...