background image

 

WR-30 Point-to-Point Wireless Bridge

 

Instruction Manual 

 

 

 

 

 

Division of Garner Industries 
7201 North 98th Street 
Lincoln, NE 68507-9741 
(402) 434-9102

 

 

Wireless System

 

 
 
 
 

 

  Signal Wire Replacement in a Rugged, Industrial Housing 

  Simple to Order, Configure, & Install 

  Range: 1 Mile Line-of-Sight, 500 ft. Indoor 

  Analog & Digital Inputs and Outputs, RS-485 Communications 

  Remote or Attached Antenna 

  Repeaters Available 

  Repeaters and Directional Antennas Available 

  Flanges for Wall or Pipe Mounting 

  PC Software Available for Even Easier Setup 

  Rugged, NEMA 4X/IP68 Enclosure 

 

 

Содержание WR-30 Series

Страница 1: ...eplacement in a Rugged Industrial Housing Simple to Order Configure Install Range 1 Mile Line of Sight 500 ft Indoor Analog Digital Inputs and Outputs RS 485 Communications Remote or Attached Antenna...

Страница 2: ...where malfunctioning could result in personal injury or property loss Anyone using this product for such applications does so at their own risk BinMaster shall not be held liable for damages resultin...

Страница 3: ...re 16 Display Functions Messages 17 Primary Unit 17 Secondary Unit 18 Setup Menu 19 Entering Numeric Values 19 Primary Device Menus 20 Secondary Device Menus 23 Display Signal I O and Digital I O Stat...

Страница 4: ...casts it to a second WR 30 unit The secondary unit then recreates that signal at its location The secondary unit may also transmit its own analog discrete or Modbus signals back to the primary unit Ju...

Страница 5: ...1 5 pipe or wall mounting See Mounting Dimensions on page 31 for mounting space requirements Signal Connector Tightening Torque 2 5 lb in 0 28 Nm Shipping Dimensions 17 x 14 x 9 43 2 cm x 35 6 cm x 2...

Страница 6: ...ut 24 dBm 250 mW Sensitivity 101 dBm RS 485 Modbus RTU Serial Comms Compatibility EIA 485 Connectors Removable screw terminal connector Max Distance 3 937 1 200 m max Baud Rate 1200 57 600 bps Data 8...

Страница 7: ...e performed only by trained service personnel Service requiring replacement of internal components must be performed at the factory Installation All pushbuttons and wiring connectors are accessed by o...

Страница 8: ...e may not cause harmful interference and ii this device must accept any interference received including interference that may cause undesired operation IMPORTANT The RF module has been certified for r...

Страница 9: ...d on the base one internal and one external Static electricity can damage sensitive components Observe safe handling precautions for static sensitive components Use proper grounding procedures codes W...

Страница 10: ...wireless device Power WR 30 and 2 Wire Transmitter from Same Power Supply The WR 30 wireless units may be powered from the same power supply that powers the 2 wire loop powered transmitter assuming th...

Страница 11: ...itted wirelessly 4 20 mA Output Connector The 4 20 mA output corresponds with the analog input signal on the paired wireless device The analog output signal is always 4 20 mA regardless of the input t...

Страница 12: ...igital output Modbus RTU Serial Communications The WR 30 acts as a simple pass through for Modbus communications As such multiple Modbus enabled devices may be transmitted wirelessly using the WR 30 W...

Страница 13: ...ection The calibration equipment is certified to NIST standards Overview There are no jumpers to set for wireless device input selection Setup and programming is done through the programming buttons l...

Страница 14: ...Signal Strength Indicator Indicates the wireless signal strength between wireless devices on a scale of 1 to 10 Enter Select a menu item of option RT Receiving Transmitting Flashes while the devices...

Страница 15: ...order to ensure that the correct signals are reaching the units Pressing either the previous or display buttons while the device is in run mode will cycle through the unit s display modes which are i...

Страница 16: ...face underneath the enclosure cover Use of WR Manager is required for programming advanced settings such as wireless encryption and analog signal calibration Note Units must be powered externally pri...

Страница 17: ...tion to input OUTPUT Set the selected digital connection to output DIGITAL I O 2 Displays digital connection 2 s current setting press enter to change DIGITAL I O 3 Displays digital connection 3 s cur...

Страница 18: ...on NETWORK ID Displays the point to point wireless network ID press enter to change 01 99 The network ID can be any number between 01 and 99 ANALOG INPUT Displays the current analog input type press e...

Страница 19: ...tion will be an output on the secondary unit Because of this the secondary wireless unit has fewer menu options than the primary unit Primary Device Secondary Device Entering Numeric Values Numeric va...

Страница 20: ...input is capable of accepting a 0 to 10 VDC signal 0 to 5 VDC signal or 1 5 VDC signal Digital I O Setup All four digital connections may be set as either inputs or outputs The setting on the primary...

Страница 21: ...meout sets the length of time the wireless devices will wait for a reply from the other Modbus device before returning an error This should be 1 to 2 seconds at 9600 bps on the primary device Modbus B...

Страница 22: ...u will be required to enter that password before being allowed to access the device menu Note Setting a password will require you to enter the password to access the device settings via the PC softwar...

Страница 23: ...ary device has fewer menu options than the primary device shown below Display Signal I O and Digital I O Status Pressing either the previous or display buttons while the device is in run mode will cyc...

Страница 24: ...can be found on the included CD Once the software is running power the unit using a 12 28 VDC power supply and connect the device to the PC using the provided USB cable The PC will automatically insta...

Страница 25: ...WR 30 Point to Point Wireless Bridge Instruction Manual 25 Calibration Analog Input Calibration 4 20mA Output...

Страница 26: ...evice communication can be secured by enabling 128 bit AES encryption A channel mask may also be set for interference immunity The encryption key and channel mask may be entered on the Advanced tab On...

Страница 27: ...mounting higher Ensure antennas are on parallel plane Devices that are vertically separated will not have as strong of a connection If communicating over distance of miles consider installing WR 30 R...

Страница 28: ...ices Check wiring diagrams starting on page 9 Digital inputs are not corresponding with digital outputs Devices have mismatched input output settings Check to make sure the digital connection is progr...

Страница 29: ...be downloaded at www binmaster com USB cable is faulty Try connecting the wireless device using a known good micro USB cable Any standard USB A to micro USB B cable such as the one used to charge a s...

Страница 30: ...for the particular application Model ___________________ S N __________________ Date _______________ Primary Parameter Default Setting User Setting ANALOG INPUT 4 20mA DIGITAL I O 1 INPUT DIGITAL I O...

Страница 31: ...ons Side Cross Section View Note The supplied conduit plug may extend up to 0 6 in 15 mm from the conduit opening when installed PDA6963 BM Stainless Steel Pipe Mounting Kit Figure 11 PDA6963 BM Stain...

Страница 32: ...Garner Industries 7201 North 98th Street Lincoln NE 68507 9741 402 434 9102 www binmaster com P O Box 29709 Lincoln NE 68529 Fax 402 434 9133 Email info binmaster com 925 0381 LIMW30BM_A SFT102 Ver 1...