background image

Decimal Display with Bargraph

Feet & Inches Display

www.binmaster.com

DPM-400

Loop-Powered Process Meter

FEATURES

    

4-20 mA Input

 

Loop-Powered Process Meter

 

1.5 Volt Drop (4.5 Volt Drop with Backlight)

  

Loop-Powered Backlight with Red Backlight for  

Alarm Conditions

 

NEMA 4X, IP65 Front

- 40 to 167°F (-40 to 75°C) Safe Area Operating 

Temperature Range

 

Free PC-Based USB Programming Software

 

5-Digit Alphanumeric Top Line

 

8-Digit Alphanumeric Bottom Line

  

Displays Level in Feet & Inches up to 999 Feet,  

 11 & 15/16 Inches

 

20-Segment Bargraph with Numeric Percent Indication

  

Conformal Coated PCBs for Dust & Humidity Protection

 

Two Open Collector Outputs Standard

 

Optional Loop-Powered Solid-State Relays

 

Optional 4-20 mA Analog Output

 

Relay Pump Alternation Based on Level and Runtime

 

Display Relay Runtime and Cycle Count

Содержание DPM-400

Страница 1: ...Safe Area Operating Temperature Range Free PC Based USB Programming Software 5 Digit Alphanumeric Top Line 8 Digit Alphanumeric Bottom Line Displays Level in Feet Inches up to 999 Feet 11 15 16 Inche...

Страница 2: ...hese loop powered meters can be installed virtually anywhere because they get their power from the 4 20 mA loop and therefore require no separate power source And they only drop 1 5 V 4 7 V with backl...

Страница 3: ...process is at certain DPM 400 models are available with a 20 segment bargraph This bargraph also includes a numeric value of the percentage the bargraph represents PV on the top line units and tag tog...

Страница 4: ...and the relays are not available with pulse features The open collectors and relays can be controlled either automatically or manually The alarm status with flashing red message will show on the disp...

Страница 5: ...mmodate under and over ranges from 1 to 23 mA The output can be reverse scaled such that the meter s high calibration value outputs 4 mA and the meter s low calibration outputs 20 mA PUMP CONTROL DPM...

Страница 6: ...inputs for instance 0 0 and 2000 0 Round Horizontal Tank Linearization This function automatically calculates the volume in a round horizontal tank with flat ends Square Root Linearization The square...

Страница 7: ...ow a 4 20 mA loop connected to the meter The first figure shows the connection without the backlight and the second shows the connection with the backlight The meter is powered by the 4 20 mA current...

Страница 8: ...t Powered by 4 20 mA loop Intensity varies with signal level PD6603 BM Top line 99FT 11IN 15 16 to 999FT 11IN 15 16 Bottom line 8 digits 9 999 999 to 99 999 999 separated by commas or 8 characters all...

Страница 9: ...set after cleared manual reset only after alarm has cleared Alarm Indication Red backlight flashing display alarm symbol symbols not available on bargraph models Bargraph segment flashes on alarm Alar...

Страница 10: ...ed to The Relay Output window is used to assign a specific task to the 2 relays such as alarm sample timer stopwatch or off A custom message that will flash every 10 seconds can also be added The 4 20...

Страница 11: ...Powered General Purpose Feet Inches Two Solid State Relays PD6603 L3N BM Loop Powered General Purpose Feet Inches 4 20 mA Analog Output PD6603 L5N BM Loop Powered General Purpose Feet Inches Two Solid...

Отзывы: