CNCR-190 • Two-wire 4-20 mA/HART  

3

Information, note, tip:

 This symbol indicates helpful additional information and tips.

Note:

 This symbol indicates notes to prevent failures, malfunctions, damage to devices  

or facility.

Caution: 

Non-observance may result in personal injury.

Warning:

 Non-observance may result in serious or fatal personal injury.

Danger: 

Non-observance of the information marked with this symbol results in serious  

or fatal personal injury.

Ex applications

This symbol indicates special instructions for Ex applications.

List

The dot set in front indicates a list with no implied sequence.

Sequence of actions

Numbers set in front indicate successive steps in a procedure.

Battery disposal

This symbol indicates special information about the disposal of batteries and accumulators.

1  About this document

2  For your safety

2.1  Authorized personnel

All operations described in this documentation must be carried out 

only by trained, qualified personnel 

authorized by the plant operator. Required personal protective equipment must always be worn when 

working on or with the device.

2.2  Appropriate use

CNCR-190 is a sensor for continuous level measurement.

Operational reliability is ensured only if the instrument is properly used according to the specifications 

in the operating instructions.

2.3  Warning about incorrect use

Inappropriate or incorrect use of this product can result in application 

specific hazards, e.g. vessel 

overfill by incorrect mounting or adjustment. Damage to property and persons or environmental

contamination can result. 

Содержание CNCR-190

Страница 1: ...CNCR 190 Two wire 4 20 mA HART 1 Operating Instructions Radar sensor for continuous level measurement of liquids CNCR 190 Two wire 4 20 mA HART Document ID 925 0398 Rev B...

Страница 2: ...ctions 6 4 2 Mounting versions 6 4 3 Mounting instructions 6 5 Connecting to power supply 10 5 1 Preparing the connection 10 5 2 Wiring plan 10 6 Setup with smartphone tablet Bluetooth 11 6 1 Preparat...

Страница 3: ...ure Battery disposal This symbol indicates special information about the disposal of batteries and accumulators 1 About this document 2 For your safety 2 1 Authorized personnel All operations describe...

Страница 4: ...inciple of operation CNCR 190 is a radar sensor for continuous level measurement It is suitable for liquids and solids in practically all industries The instrument emits a continuous frequency modulat...

Страница 5: ...tebook Devices with signal output 4 20 mA HART can also be operated via a signal cable This is done via an interface adapter and a PC notebook using DTM PACTware Fig 3 Connecting the PC to the signal...

Страница 6: ...ed G1 plastic nut Take note of Figure 4 for the recommended distance to the wall Fig 4 Mounting via a mounting bracket 4 3 Mounting instructions The radar emits pulses of electromatic waves which are...

Страница 7: ...aintain this distance you should carry out a false signal suppression during initial setup This applies particularly if buildup on the vessel wall is expected If this is the case we recommend repeatin...

Страница 8: ...am The antenna edge of the device is the beginning of the measuring range and at the same time the reference plane for the min max adjustment see following diagram Do not mount the instruments in or a...

Страница 9: ...ecommended values for socket or stand pipe lengths and heights are in the following table The values come from typical applications For socket or stand pipe mount the pipe should be as short as possib...

Страница 10: ...arresters should be installed Warning Only connect or disconnect in de energized state Note Power the instrument via an energy limited circuit power max 100 W according to IEC 61010 1 e g Class 2 powe...

Страница 11: ...searches automatically for Bluetooth capable instruments in the area The message Connecting is displayed The devices found are listed and the search is automatically continued Select the requested in...

Страница 12: ...is deactivated which is default Parameter protection can be activated later if desired 6 3 Parameter adjustment The sensor adjustment menu is divided into two areas which are arranged next to each ot...

Страница 13: ...sensor Max adjustment 0 0 m Min adjustment 8 0 m Menu item Selection Basic settings Damping Integration time 0 s Current output Output characteristics 4 to 20 mA 0 to 100 Current range Min current 3 8...

Страница 14: ...5 F017 Adjustment span too small Adjustment not within specification Change adjustment according to the limit values difference between min and max 10 mm Byte 5 Bit 1 of Byte 0 to 5 F025 Error in the...

Страница 15: ...inish simulation Wait for the automatic end after 60 min Simulation Active in Standardized Status 0 Code Text message Cause Rectification F105 Determine measured value The instrument is still in the b...

Страница 16: ...Error when carrying out a reset False signal suppression faulty Carry out reset and repeat setup Bit 7 of Byte 14 to 24 M508 Data error in program memory Bluetooth controller Bit 8 of Byte 14 to 24 M5...

Страница 17: ...ted parts Antenna PVDF Counter nut depending on device version PP Materials non wetted parts Housing PVDF Cable entry seal NBR Connection cable PUR Weight Instrument 0 7 kg 1 543 lbs Connection cable...

Страница 18: ...76 F Storage and transport temperature 40 to 80 C 40 to 176 F Process conditions For the process conditions please also note the specifications on the type label The lowest value amount always applies...

Страница 19: ...CNCR 190 Two wire 4 20 mA HART 19 11 2 Dimensions CNCR 190 Fig 16 Dimensions CNCR 190...

Страница 20: ...l use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior notice BinMaster Phone 402 434 9102...

Отзывы: