Binks MAG HVLP 4006-1100-0 Скачать руководство пользователя страница 8

MaG HVLP aUtoMatic SPRaY GUn

Standard Needles: • 90PF—Feathering (DELRIN)  • AB—Standard (DELRIN)

Optional Needles: • 90SF—Feathering (S.S.) 

• ABSS—Standard (S.S.)

cLeaninG Kit

PaRt no.  deScRiPtion

54-4994 

 Cleaning Kit: includes one standard stiff nylon pipe 

cleaning brush, full-size nylon brush, tip cleaner, and 

Binks Gunners Mate Lubricant

RePaiR Kit

54-5307 

 REBUILD KIT CONSISTS OF: 

2 EA 

20-3467 

RING O 1/4 ID X 3/8 OD 

1 EA 

20-6784 

O-RING 

4 EA 

20-4615 

O-RING 

2 EA 

20-6786 

O-RING 

1 EA 

20-5921 

O-RING 

2 EA 

20-6785 

O-RING 

2 EA 

20-6783 

O-RING 

1 EA 

54-5331 

PISTON IMPACT RINGS

acceSSoRieS

PaRt no.  deScRiPtion

54-380 

Gun Mounting Bracket

54-1835 

 100 Mesh Filter

54-1836 

 60 Mesh Filter

54-5340 

Filter Retainer Assembly

54-3918 

Gun Wrench

6-428 

Gun Lube (2 oz. bottle)

6-429 

Gun Lube (20 bottles ref only)

83-2484 

Fluid Inlet Stainless Nipple 1/4 NPT x 3/8 NPS

54-5303 

Standard Performance Seal Kit

54-5307 

High Performance Seal Kit

54-5308 

Dual Port Conversion Kit

HoW to oRdeR

**NOTE: Order fluid nozzles, needles and air cap separately.

GUn coMBinationS aVaiLaBLe aS StandaRd WitHoUt aiR caPS

(oRdeR aiR nozzLeS SePaRateLY)

 

SUPPLied WitH GUn

  

  fLUid 

 

 

 

 

 

 

fLUid nozzLe 

 

 

 

 

 deSiGnation 

nozzLe 

oRifice 

fLUid 

fLUid 

 

 

  nUMBeR WitH 

oRifice 

aPPRoX. 

nozzLe 

needLe 

 

aPPLicaBLe 

 

ManifoLd 

(incHeS) 

(MM) 

deSiGnation 

deSiGnation 

needLe tYPe 

 aiR nozzLeS*

  4006-1100-0 

0.040 

1.02 

91 

AB 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4006-1200-0 

0.055 

1.40 

94 

AB 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4006-1300-0 

0.070 

1.78 

97 

AB 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4006-1400-0 

0.030 

0.76 

90 

AB 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4006-1500-0 

0.020 

0.51 

88 

90PF 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4006-1600-0 

0.045 

1.14 

92 

AB 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4006-4900-0 

0.025 

0.64 

89A 

90PF 

STANDARD – DELRIN TIP 

90P, 92P, 94P, 100P

  4008-1100-0 

0.040 

1.02 

91 

ABSS 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

  4008-1200-0 

0.055 

1.40 

94 

ABSS 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

  4008-1300-0 

0.070 

1.78 

97 

ABSS 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

  4008-1400-0 

0.030 

0.76 

90 

90SF 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

  4008-1500-0 

0.020 

0.51 

89 

90SF 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

  4008-1600-0 

0.045 

1.14 

92 

ABSS 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

  4008-4900-0 

0.025 

0.64 

89A 

90SF 

STANDARD – STAINLESS 

90P, 92P, 94P, 100P

*Air caps are selected based on fluid flow rates and fluid viscosities. Consult Binks Tech Support team for further details.

 

 

fLUid nozzLe 

 

 

 

 

 deSiGnation 

nozzLe 

oRifice 

fLUid 

fLUid 

 

 

  nUMBeR LeSS 

oRifice 

aPPRoX. 

nozzLe 

needLe 

 

aPPLicaBLe 

    ManifoLd** 

(incHeS) 

(MM) 

deSiGnation 

deSiGnation 

needLe tYPe 

aiR nozzLeS

 4007-0000-0 

NOT SUPPLIED

 

NOT SUPPLIED

 

NOT SUPPLIED

 

NOT SUPPLIED

 

NOT SUPPLIED

 

NOT SUPPLIED

2/13   ©2013 Binks   All rights reserved.   Printed in U.S.A.

U.S.a./canada customer Service
195 Internationale Blvd. 

Glendale Heights, IL 60139 

630-237-5000 

Toll Free Customer Service 

and Technical Support 

800-992-4657
Toll Free Fax 

888-246-5732

Binks Sales and Service: www.binks.com

WaRRantY  

This product is covered by Binks’ 1 Year Limited Warranty.

77-2803R-11 Revisions: Trademark updates; 
(P8) Updated contact information.

Содержание MAG HVLP 4006-1100-0

Страница 1: ...ation presented call your nearest service representative Part Sheet 77 2803R 11 Specifications Max Air Pressure 100 psi 6 8 bar For HVLP compliance See page 5 Max Fluid Pressure 120 psi 8 3 bar Min Ma...

Страница 2: ...ghted sound level of spray guns may exceed 85 dB A depending on the setup being used It is recommended that ear protection is worn at all times when spraying PROP 65 WARNING WARNING This product conta...

Страница 3: ...creasing the air pressure to the fan port GENERAL SPRAY INSTRUCTIONS 1 Minimum cylinder actuating pressure is 50 PSI 2 To reduce overspray and obtain maximum efficiency always spray with the lowest po...

Страница 4: ...Remove fluid needle assembly 8 3 Using the two 8 32 screws 41 provided in loose parts bag thread the two 8 32 screws into the two threaded holes in the back of the piston Pull the two threaded screws...

Страница 5: ...up on tip or Clean tip tip partially plugged On defective side of pattern air horn Clean air horn holes with solvent and holes are plugged a soft brush Pattern pushed to On defective side of pattern...

Страница 6: ...TOMIZING AIR REGULATOR fLUid RetURn fLUid RetURn GROUND GROUND Hose Hook Up with Atomizing Fan Air COMBINED Hose Hook Up with Atomizing Fan Air SEPARATED IMPORTANT REGULATORY NOTE Some regulatory agen...

Страница 7: ...E 2 27 54 5326 Fluid Manifold Port Plug 2 28 54 3918 Gun Wrench not shown 1 30 20 5921 O Ring 2 017 PTFE 1 ITEM PART NO NO DESCRIPTION QTY 31 54 3720 Side Port Control Assembly 1 32 54 5358 Air Fluid...

Страница 8: ...P 100P 4006 1300 0 0 070 1 78 97 AB STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1400 0 0 030 0 76 90 AB STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1500 0 0 020 0 51 88 90PF STANDARD DELRIN TIP 90P 92P 94...

Отзывы: