toXic fLUid HazaRd

•  Know the specific hazards of the fluid you 

are using. this information is on the MSdS 

for the material being used. Read all fluid 

manufacturer warnings.

•   Store hazardous fluids in approved 

containers only. dispose of all hazardous 

fluids in accordance with all state, local and 

national guidelines.

•  Wear the appropriate protective clothing, 

gloves, eyewear and respirator.

equipment misuse can cause the equipment 

to fail, malfunction, or start unexpectedly 

and result in serious injury.

fiRe and eXPLoSion HazaRd

•  Ground the equipment and object being 

sprayed.

•  Provide fresh air ventilation to avoid the 

build up of flammable fumes from the 

material being sprayed or from solvent.

•  extinguish all open flames or pilot lights in 

spray area.

•  electrically disconnect all equipment in the 

spray area.

•  Keep the spray area free from all debris, 

including solvent rags.

•  if there is any static sparking while using 

the equipment, StoP SPRaYinG 

iMMediateLY. identify and correct the 

problem.

eQUiPMent MiSUSe HazaRd

• this equipment is for professional use only.

•  Read and understand all instructional 

manuals, tags, and labels before operating 

equipment.

•  Use the equipment only for its intended 

purpose. if you are unsure about its 

purpose call your local Binks distributor.

•  do not alter or modify this equipment. Use 

only genuine Binks parts.

•  do not exceed the maximum working 

pressure of the lowest rated system 

component. tHe MaXiMUM 

RatinG of tHe MaG HVLP GUn iS 120 P.S.i. 

do not eXceed tHe fLUid PReSSURe 

RatinG.

•  Route all hoses away from all sharp edges, 

moving parts, hot surfaces and high traffic 

areas.

• do not use hoses to pull the equipment.

• Use only Binks approved hoses.

•  Use only solvents compatible with hoses 

and wetted parts of the equipment used.

•  comply with all applicable local, state and 

national fire, electrical and other safety 

regulations.

•  improper grounding, poor air ventilation, 

open flame or sparks can cause a hazardous 

condition and result in fire or explosion and 

cause serious injury.

noiSe LeVeLS

•  the a-weighted sound level of spray guns 

may exceed 85 dB(a) depending on the 

setup being used. it is recommended that 

ear protection is worn at all times when 

spraying.

PRoP 65 WaRninG

•  WaRninG: this product contains chemicals 

known to the State of california to cause 

cancer and birth defects or other 

reproductive harm.

  

Warning

HiGH PReSSURe can caUSe SeRioUS injURY if 

eQUiPMent iS inStaLLed oR USed incoRRectLY— 

REad, undERStand, and obSERVE

 aLL WaRninGS 

and inStRUctionS in tHiS ManUaL.

oPeRate eQUiPMent onLY afteR aLL 

inStRUctionS aRe cLeaRLY UndeRStood.

!

fLaMMaBLe, eXPLoSiVe and toXic VaPoRS

In this part sheet, the words 

WaRninG

caUtion

 and 

note

 are used to emphasize important safety information as follows:

 caution

Hazards or unsafe practices which could 

result in minor personal injury, product 

or property damage.

!

   WaRning

Hazards or unsafe practices which could 

result in severe personal injury, death or 

substantial property damage.

!

notE

important installation, operation or 

maintenance information.

The automatic Spray Gun models listed in the following declaration of conformity may be used in some potentially explosive atmospheres 

ONLY when the special conditions for safe installation and operation have been followed as expressed in this user manual (Part Sheet). 

These models are approved to ATEX regulations 94/9/EC, protection level: ii 2 G X: Suitable for use in zones 1 and 2.

ec declaration of conformity

Manuf. By: 

 Finishing Brands 
195 Internationale Blvd. 
Glendale Heights, IL 60139

Type/Series: 

Manifold Mounted Automatic Spray Guns

Model:  MAG HVLP: 4006-, 4007-, 4008-, 4009-

The equipment to which this document relates is in conformance with the following standards or other normative references:

en iSo 12100-1&2:2003 and BS en 1953:1999 and thereby conform to the protection requirements of Council Directive 98/37/
EC relating to Machinery Safety Directive, and;

en 13463-1:2001, Council Directive 94/9/ec relating to equipment and Protective Systems for use in Potentially explosive 
atmospheres
, protection level ii 2 G X.

Approved By:   _____________________________  Date: ____________  

 

Chuck McCulloch, Finishing Brands

Finishing Brands reserves the right to modify equipment specification without prior notice.

April 17. 2006

Содержание MAG HVLP 4006-1100-0

Страница 1: ...ation presented call your nearest service representative Part Sheet 77 2803R 11 Specifications Max Air Pressure 100 psi 6 8 bar For HVLP compliance See page 5 Max Fluid Pressure 120 psi 8 3 bar Min Ma...

Страница 2: ...ghted sound level of spray guns may exceed 85 dB A depending on the setup being used It is recommended that ear protection is worn at all times when spraying PROP 65 WARNING WARNING This product conta...

Страница 3: ...creasing the air pressure to the fan port GENERAL SPRAY INSTRUCTIONS 1 Minimum cylinder actuating pressure is 50 PSI 2 To reduce overspray and obtain maximum efficiency always spray with the lowest po...

Страница 4: ...Remove fluid needle assembly 8 3 Using the two 8 32 screws 41 provided in loose parts bag thread the two 8 32 screws into the two threaded holes in the back of the piston Pull the two threaded screws...

Страница 5: ...up on tip or Clean tip tip partially plugged On defective side of pattern air horn Clean air horn holes with solvent and holes are plugged a soft brush Pattern pushed to On defective side of pattern...

Страница 6: ...TOMIZING AIR REGULATOR fLUid RetURn fLUid RetURn GROUND GROUND Hose Hook Up with Atomizing Fan Air COMBINED Hose Hook Up with Atomizing Fan Air SEPARATED IMPORTANT REGULATORY NOTE Some regulatory agen...

Страница 7: ...E 2 27 54 5326 Fluid Manifold Port Plug 2 28 54 3918 Gun Wrench not shown 1 30 20 5921 O Ring 2 017 PTFE 1 ITEM PART NO NO DESCRIPTION QTY 31 54 3720 Side Port Control Assembly 1 32 54 5358 Air Fluid...

Страница 8: ...P 100P 4006 1300 0 0 070 1 78 97 AB STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1400 0 0 030 0 76 90 AB STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1500 0 0 020 0 51 88 90PF STANDARD DELRIN TIP 90P 92P 94...