background image

TYPES OF INSTALLATION

2

5/16"

1/4"

Only 34 PSI at gun inlet

25 feet of 1/4" I.D. hose causes
a drop of 26 PSI between the
air supply and the gun.

(NOT RECOMMENDED)

48 PSI at gun inlet

25 feet of 5/16" I.D. hose
causes a drop of 12 PSI
between the air supply 
and the gun. For this reason
Binks recommends the use 
of 5/16" hose.

(RECOMMENDED)

With 60 psi applied at air supply

CONNECTING GUN TO
“PRESSURE ASSISTED” 1 QT. CUP
(Figure 1)

The stainless steel pressure-assisted 
1-quart cup, 80-272, utilizes a low 
pressure air bleed port on the gun head to
slightly pressurize the cup and provide
fluid flow to the nozzle. A check valve
prevents the cup from depressurizing 
when the gun trigger is released and 
airflow stops.

To connect the gun to the cup, remove the
plug (35) in the gun head and install the
hose barb fitting provided with cup assem-
bly. Attach cup assembly to 3/8" NPS fluid
inlet connection and firmly tighten. The
siphon tube should be angled toward the
front of the gun, i.e. under the nozzles,
and the pressure hose in the cup lid posi-
tioned to the left of the trigger. Connect
check valve assembly hose from bard fit-
ting on gun head to check valve inlet fit-
ting on cup cover. Make sure the check
valve is connected so the air comes from
the gun, through the check valve, into 
the cup.

Air pressure for atomization is regulated 
at the extractor. The flow of the fluid is
adjusted by the fluid valve control 
knob on gun, viscosity of paint and 
air pressure.

PRESSURE CUP HOOKUP
(Figure 2)

For fine finishing with limited spraying.
Air pressure for atomization is regulated 
at extractor; fluid pressure at cup regula-
tor. pressure cup is also available less 
regulator.

PRESSURE TANK HOOKUP
(Figure 3)

For medium production spraying (single
regulator). Air pressure for atomization is
regulated at extractor, fluid pressure at
tank regulator.

PRESSURE TANK WITH
2 REGULATORS (Figure 4)

The pressure to the tank is regulated by
the first regulator. The pressure for 
atomization is regulated by the second
regulator.

PRESSURE CIRCULATING
HOOKUP (Figure 5)

For heavy production spraying. Air 
pressure atomization regulated at extractor.
Fluid pressure regulated at fluid regulator.

AIR PRESSURE

Atomizing pressure must be set 
properly to allow for the drop in 
air pressure between the regulator 
and the spray gun.

Binks oil and water extractor is important

.

Achieving a fine spray finish without the use of a good oil and water extractor is virtually
impossible.

A Binks regulator/ extractor serves a double purpose. It eliminates blistering and spotting by
keeping air free of oil and water, and it gives precise air pressure control at the gun. 

Binks recommends using the HFRL-508 oil and water extractor / regulator. 
See your local distributor for models.

Cross section view 

showing comparison of inside

hose diameters (actual size). 

60 lbs. regulated pressure

Air

Oil & Water
Extractor

Fluid Pressure Cup

FIG 3

Air

Fluid
Outlet

Air
Inlet

Oil & Water Extractor

Fluid

Pressure

Tank

FIG 4

FIG 5

Fluid
Regulator

Air Supply

Air Supply

Fluid

Pressure

Tank

Oil &
Water
Extractor

Air

FIG 1

FIG 2

Air

Cup Regulator

Oil & Water
Extractor

Fluid

Pressure-Assisted Cup

Содержание MACH 1SL

Страница 1: ...ce with the California South Coast Air Quality Management District regulations as a high volume low pressure airspray gun The air inlet passage in the gun body incorporates a venturi which limits air...

Страница 2: ...E CUP HOOKUP Figure 2 For fine finishing with limited spraying Air pressure for atomization is regulated at extractor fluid pressure at cup regula tor pressure cup is also available less regulator PRE...

Страница 3: ...tainer and release the pressure on the container Hold a piece of cloth wadded in the hand over the gun nozzle 3 and pull the trigger The air will back up through the fluid nozzle and force the fluid o...

Страница 4: ...IPTION QTY 25 54 4370 SEAL CARTRIDGE ASSEMBLY Mach 1SL and Mach 1SLA 1 26 54 4330 ADJUSTABLE FLUID INLET ASSEMBLY Mach 1SLA 1 27 54 4133 GUN BRUSH Optional 1 28 54 3918 WRENCH Not Included Optional 29...

Страница 5: ...more gradual fluid valve opening for metering control of fluid flow with trigger SIPHON FEED FINE FINISH Light to medium fluids Auto body spot repairs Medium to heavy fluids Auto body overall finishi...

Страница 6: ...0 22 5 50 0 64 0 NOZZLE ATOMIZING PSI NOZZLE AIRFLOW SCFM SIDE PORT CONTROL 3 0 4 5 6 0 9 0 5 0 6 0 8 5 10 0 7 0 6 8 11 0 14 0 9 0 7 5 13 5 18 0 10 0 8 0 15 0 19 0 NOTE Regulator pressures are based...

Страница 7: ...n ADJUSTING THE NEEDLE ASSEMBLY do not make any alterations in the gun To do so could cause finishing difficulties 3 To clean nozzles soak them in solvent to dissolve any dried material then blow them...

Страница 8: ...LATORY NOTE Part Number Description 54 3908 900 SERIES 54 3935 95 and 97 SERIES 95AP and 97AP 54 4078 95AS and 97AS NOZZLES Siphon 54 4345 90P NOZZLE 54 4356 93P NOZZLE 54 4066 94P NOZZLE 54 4566 96G...