CAUTION
To prevent damage to fluid tip or fluid needle, be sure to either:
1.
Pull the trigger and hold while tightening or loosening the fluid tip, or,
2.
Remove the fluid adjusting knob to relieve spring pressure against needle collar.
SUCTION/GRAVITY CUP.
Empty excess material and clean the cup. Make sure the vent holes in the diaphragm and the
lid are clear.
SPRAY GUN MAINTENANCE & CLEANING
To clean air cap and fluid tip, brush exterior with a stiff bristle brush. If necesarry to clean cap holes,
use a broom straw or toothpick if possible. If a wire or hard instrument is used, extreme care must
be taken to prevent scratching or burring of the holes which will cause a distorted spray pattern.
To clean fluid passages, remove excess material, then flush with gun wash solution. Wipe the gun
exterior with a dampened cloth. Never completely immerse in any solvent or cleaning solutions as
this is detrimental to the lubricants and life of the spray gun.
NOTE
When replacing the fluid tip or fluid needle, replace both at the same time. Torque to 18-20 Nm [160-
180 lbs.in]. Do not over tighten the fluid tip. Use spanner supplied with the gun and check with a
torque wrench.
NOTE
When removing air cap from retaining ring, do not remove the ring seat from the retaining ring.
Damage to the parts may occur. Simply wipe parts clean and reassemble with new or clean air cap.
SB-E-2-852 R2.0
8/20
www.carlisleft.com
Содержание EMG Series
Страница 13: ...EN DISASSEMBLY SPRAYHEAD reverse for assembly SB E 2 852 R2 0 13 20 www carlisleft com ...
Страница 17: ...EN NOTES SB E 2 852 R2 0 17 20 www carlisleft com ...
Страница 18: ...EN NOTES SB E 2 852 R2 0 18 20 www carlisleft com ...
Страница 19: ...EN NOTES SB E 2 852 R2 0 19 20 www carlisleft com ...