EN
Heavy centre pattern.
Material too thick.
Thin to correct consistency.
Atomising air pressure too low.
Increase air pressure.
Intermittent or 'fluttering'
spray fan.
Loose fluid tip.
Tighten.
Fluid tip not seated correctly in gun
head.
Remove fluid tip, clean components,
check cone seating on tip and gun
for damage or contamination.
Partially obstructed fluid passage or
hose.
Clean or replace.
Split spray pattern
Not enough material flow.
Increase fluid flow by changing fluid
tip size, opening needle control knob
or increase fluid pressure on
pressure feed container.
Too high horn pressure.
Reduce air pressure by rotating
pattern control valve clockwise.
Too much air for fluid quanitity used. Reduce input air pressure.
Pattern adjustment valve set too low.
Turn out counter clockwise to
achieve correct pattern.
Too much material.
Reduce fluid flow by turning fluid
needle adjusting screw clockwise.
Reduce fluid pressure.
SB-E-2-852 R2.0
15/20
www.carlisleft.com
Содержание EMG Series