Fluid inlet connection: 'A'
Fluid outlet connection: 'B'
Gearbox Ratio:
56:1
460V 3PH 1 Hp @ 60HZ
Class 1, Group D.
Total Weight of Pump (inc electric motor)
Fluid Output @ 80 HZ [40 cycles/min]
60 l/m [16.0 US gal/m]
2 bar [29 psi]
Reduce Maximum working pressure by 2 bar [29 psi] when using in Open Loop Flow Mode
Fluid Output @ 20 HZ [10 cycles/min]
15 l/m [4.0 US gal/m]
Max. Inlet Pressure
e.g. E2-60 Maximum Set Pressure of 18 bar to operate Pump on a 24/7 basis
NOTE
Gearbox Oil (EU Model)
Synthetic 220 (typically Agip Blasia S)
Gearbox Oil (USA Model)
1.50 l/m [0.40 US gal/m]
EN
SPECIFICATION
Nominal pump stroke:
50mm [1.97 ins]
20 bar [290psi]
3.0 kW 4Pole 1400 RPM
EEx d 11B T3
295kg [650lbs]
E2-60 Nominal flow volume / cycle:
E2-60* Maximum fluid pressure:
1 ½'' Sanitary
1 ½'' Sanitary
SHC 630 Synthetic Oil
* Pressure when used in 'Smart Mode' (Closed Loop Pressure Mode)
AC Induction Electric Motor- EU Model
400V 3PH 3.0 kW @ 50HZ
3.0 kW 4Pole 1400 RPM - Japan Model
Rated 20 to 80 Hz (c/w thermisters)
AC Induction Electric Motor - USA Model
Rated 20 to 80 Hz (c/w thermisters)
77-3228 R3.3
4/36
www.carlisleft.com