5.3
Behavior after power failure
After power return, the unit continues operating in the operating mode actual before power failure. In
Manual Mode (HAND), the controller regulates the temperature to the last entered set-points, while in
Program Mode (AUTO) it regulates the temperature to its set-point actually reached during program op-
eration. The power failure is noted in the event list (chap. 6.2). No error message is displayed indicating
that a power failure has taken place.
5.4
Switching on the unit
Put the main switch (2) in position I. The pilot lamp shows the unit being ready for operation.
Observe a delay time of about 30s between switching Off and On again. Otherwise an initiali-
zation problem might occur (display showing e.g. “–1999”).
In case the main switch is already in position I and yet the controller screen is dark, the chamber is in
stand-by mode. Switch on the unit by pressing any button. When switched on, the unit operates in the
operating mode entered before switching off. In Manual Mode (HAND), the controller regulates the tem-
perature to the last entered set-point, and in Program Mode (AUTO) it regulates the temperature to the
set-points reached during previous program operation.
Structure of toggling between Idle Mode / Manual Mode / Program Mode:
Idle Mode
HAND
EXIT
Menu Program start
Manual Mode (HAND)
Program Mode (AUTO)
or EXIT
Heating up time
Average heating up time approx. 5 °C/min (the air flap closed and the fan set to maximum speed).
Cooling down time
Average cooling down time approx. 0.2 °C/min to 1.5 °C/min (the air flap open and the fan set to maxi-
mum speed).
If the unit is fully loaded, the specified heating up and cooling down times may vary according
to the load.
Содержание APT.line M Series
Страница 54: ...M 01 2009 page 54 61 15 6 Dimensions M 53 ENT ENT ENT...
Страница 55: ...M 01 2009 page 55 61 15 7 Dimensions M 115 ENT ENT ENT...
Страница 56: ...M 01 2009 page 56 61 15 8 Dimensions M 240 6 8 ENT ENT ENT...
Страница 57: ...M 01 2009 page 57 61 15 9 Dimensions M 400 ENT ENT ENT...
Страница 58: ...M 01 2009 page 58 61 15 10 Dimensions M 720 ENT ENT ENT...