Press the FUNC and
▲
button
simultaneously and hold for 2 seconds to
enter the Advanced Parameters Adjusting
status.
Press the FUNC button repeatedly until
shifting to the Logical Relation Adjusting
status of the Intelligent Photoelectric
Sensor.
Adjust the parameter by pressing the
▲
or
▼
button.
Logical Relation Setting of the Intelligent Photoelectric Sensor
Under normal circumstances, the receiving end receives no optical signal, and the controller
runs by default.But in some specialapplications the controllerneeds to be stoppedwhenthe
receiving end receives nooptical signal. Adjusting thisparameter can fulfill this kind of
application.
When Logical Relation is set as
Normal Open
, namely no optical
signal received, the controller runs.
When Logical Relation is set as
Normal Close
, namely no optical
signal received, the controller stops.
17
33 SDV 31
www.binder-es.com
5. Sensor and Signal Control