20
9 - Led indicating cyclic steam enabled;
10 -
Down key: decreases the programmed value and selects the cyclic steam function, which
emits steam automatically for 6 seconds and every 2 minutes (factory default program). To reprogram the
cyclic steam, follow the instructions below;
11 -
Programming access key;
12 -
Led indicating ignition on;
13 - Led indicating heating on;
Reprogramming of single steam and cyclic steam:
To reprogram the steam time press the keys at the same time, in that
moment it will appear in the display
. Set the steam time through the keys . Press the
button
to confirm the simple steam program.
Reprogram the cyclic steam by pressing the button , the led will light up. After that,
press the keys at the same time and the display will appear . Set the steam exit
time with the keys and confirm that it will also activate the time option for each steam
cycle . After setting the interval time between each cycle, confirm with .
The controller has a system that checks for possible equipment failure. These faults can be
seen in the display.
Check the description for each failure:
Display
Description
The controller detected that the flame sensor shows a short circuit with the
burner. Check if the flame sensor is touching the burner or if there is any
point in the sensor wiring short circuit to the equipment frame.
The controller has exhausted the programmed start attempts and has
not detected the presence of a flame in the flame sensor. Check the
distance between the flame sensor and the burner and whether the flame is
present in the flame sensor.
The controller detected a failure in the temperature sensor. Verify that the
sensor is properly connected to the controller and that the sensor is not
damaged.
The controller detected a short circuit between the flame sensor and the
burner.
The controller has detected that the temperature measured by the PTC
sensor is above normal operating conditions. Check that the sensor is
properly connected to the controller and that it is not broken or damaged.
Содержание Metvisa FTG.150B
Страница 1: ......
Страница 10: ...10 Follow the guidelines below to assemble the stand ...
Страница 30: ...30 9 ANNEXES Electrical Schematic Voltage 110 V or 127 V 60 Hz NOTE FTG150 oven uses only one Door Light ...
Страница 31: ...31 Explosion Design ...
Страница 32: ...32 Explosion Design ...
Страница 33: ...33 Explosion Design ...
Страница 34: ...34 Explosion Design ...
Страница 35: ...35 Explosion Design ...
Страница 43: ...43 ...