background image

 

Page 1 of 16

 

 

BA_2005_2_GB_D2 

Replacement for BA_2005_1_GB_D2 

 

Operating instructions 

Pump  D2 

 
 
 
 
 
 
 

 

INDEX 

 Page 
 

  1.  General  ................................................................................. 2 

 

  2.  Safety .............................................................................. 2 – 4 

 

  A.  Pump type  ............................................................................ 5 

 

  B.  Kinds of dive  .................................................................. 5 – 6 

 

  C.  Inspection ............................................................................. 6 

 

  D.  Number of single pump elements  ...................................... 6 

 

  E.  Number of double pump elements ..................................... 6 

 

  F.  Number of cover plates ....................................................... 6 

 

  G.  Position of drive  .................................................................. 7 

 

  H.  Reservoir  .............................................................................. 7 

 

   I.  Accessories  ......................................................................... 7 

 

  3.  Design ................................................................................... 8 

 

  4.  Principle of operation .......................................................... 8 

 

  5.  Specification  ........................................................................ 8 

 

  6.  Installation .................................................................... 9 – 10 

 

  7.  Start-up ............................................................................... 12 

 

  8.  Subsequent modifications ................................................ 13 

 

  9.  Maintenance ............................................................... 13 – 14 

 10. 

Fault 

finding 

....................................................................... 14 

 11. 

Plates 

.................................................................................. 15 

 12. 

Manufacturer’s 

declaration 

............................................... 16 

 

Содержание D2

Страница 1: ...nspection 6 D Number of single pump elements 6 E Number of double pump elements 6 F Number of cover plates 6 G Position of drive 7 H Reservoir 7 I Accessories 7 3 Design 8 4 Principle of operation 8 5 Specification 8 6 Installation 9 10 7 Start up 12 8 Subsequent modifications 13 9 Maintenance 13 14 10 Fault finding 14 11 Plates 15 12 Manufacturer s declaration 16 ...

Страница 2: ... 2 Safety These operating instructions contain fundamental instructions which are to be observed during erection operation and maintenance Therefore it is absolutely necessary for the fitter and the competent qualified staff user to read these operating instructions before installation and start up The operating instructions must be available at all times at the place of use of the machine system ...

Страница 3: ...otected against touch Protection against touch for moving parts e g coupling must not be removed when the machine is in operation Leakages e g from the shaft seal of hazardous goods to be delivered e g explosive toxic hot are to be removed in such a way that there is no danger to persons and environment Legal rules are to be observed Hazards caused by electrical power are to be excluded for detail...

Страница 4: ... IEC I 60947 5 1 11 03 2 DIN EN 61000 6 2 8 02 IEC 61000 6 2 1 05 3 DIN EN 61000 6 3 8 02 IEC 61000 6 3 1 05 3 DIN EN 61000 6 4 8 02 IEC 61000 6 4 1 05 3 3 0 Notes on environmental protection and waste disposal In correct operation with lubricants the components are subject to the special requirements set by environmental legislation The general requirements for lubricants are specified in the res...

Страница 5: ...volume 1 x 0 2 cm3 for single pump element max 40 outlets Surface signal grey RAL 7004 A PUMP TYPE PD2 B KINDS OF DRIVE Pendulum lever Step down gear 30 1 and flange motor 230 260 V 400 460 V 50 60 Hz Step down gear 30 1 and flange motor 500 V 50 Hz Step down gear 60 1 and flange motor 230 260 V 400 460 V 50 60 Hz Step down gear 60 1 and flange motor 500 V 50 Hz Drive with pendulum lever ...

Страница 6: ...05_1_GB_D2 B KINDS OF DRIVE continuation Drive with step down gear and flange motor C INSPECTION Stage A D NUMBER OF SINGLE PUMP ELEMENTS without 1 up to 20 E NUMBER OF DOUBLE PUMP ELEMENTS without 1 up to 20 F NUMBER OF COVER PLATES without 1 up to 19 ...

Страница 7: ...ement for BA_2005_1_GB_D2 G POSITION OF DRIVE on the right oscillating lever on the right flange motor on the left flange motor Oscillating lever Flange motor H RESERVOIR 4 liters I ACCESSORIES Base Feeding element and base without base ...

Страница 8: ...sequent compression stroke the plungers force the oil out through the lines to the lubrication points with which they are connection 5 Specification Capacity of reservoir 4 liters Working temperature range 40 0 C 50 0 C Viscosity range of oil at the working temperature 40 2300 mm2 s 1 Drive max metered quantity per outlet and per delivery stroke with Permissible back pressure Weight of the pump wi...

Страница 9: ...d to the oscillating lever Permissible lever movement min 10 max 60 corresponding to 1 36 to 1 6 of a revolution of the drive shaft Max permissible rate of oscillation of lever 300 double strokes per minute Gear box with flange motor Before installing the electrical wiring check that the voltage and frequency of the available power supply is as stated on the rating plate on the flanged three phase...

Страница 10: ... the line from the overhead reservoir Filling pump Remove the plug C connect the line from the filling pump Connection R 1 4 Remove the plug B connect the overflow or return line Connection R 3 4 To connect the lines to the lubrication points Pipes and couplings Before installation carefully clean all pipes by tapping and blowing through Bend pipes cold only to avoid formation of scale Connection ...

Страница 11: ...e oil top cocks directly in at the lubrication points Connection R 1 2 Electrical connections Flange motor see Item Gear box with flange motor Heating Voltage 220 W Power 50 W Protection system IP 54 Minimum oil level monitor Voltage 42 V Make and break capacity 21 VA Switching current 0 5 A Protection system IP 65 ...

Страница 12: ...ed metered quantities If possible avoid settings close to 0 i e giving less than about 1 8 of the max metered quantities see Item 5 Specification for the max metered quantities Replace gasket an cover and secure with the screws To carry out the trial run Turn the crank until blubble free oil issues uniformly from the ends of the pipes at the lubrication points Connect the pipe ends tightly using t...

Страница 13: ... since this would give to harmful pressures 9 Maintenance To fill the reservoir The reservoir should always be topped up in good time The oil level should never be allowed to drop below the bottom of the oil sight glass otherwise air may ve drawn in Clean oil only should be used for filling Avoid all contamination ince foreign matter is the most frequent cause of failure and damage If air gets int...

Страница 14: ...nliness is essential in assembling the pump after repair since particles of dirt can cause failure and damage If major damage occurs the pump should be returned to the manufacturer for repair Pump element If the fit between plunger and cylinder has changed due to wear the complete pump element should be replaced since it is not possible in this case to service parts individually 10 Fault finding F...

Страница 15: ...Page 15 of 16 BA_2005_2_GB_D2 Replacement for BA_2005_1_GB_D2 11 Plates Name plate 110 x 60 mm 75511 1531 Type plate 110 x 60 mm 75511 1321 ...

Страница 16: ...ating data sheet both being valid for the product We Company Address Telephone DELIMON GmbH Arminstraße 15 40227 Düsseldorf 49 211 77 74 0 hereby declare on our sole responsibility that all products supplied by us and being relevant to guidelines and which this declaration refers to conform to the mentioned standards and that they if necessary were released by a competent authority Applied harmoni...

Отзывы: