8
BIJUR DELIMON INTERNATIONAL
OPERATORS MANUAL
CLP
36917 r#1
Replacing a Cartridge
Activation of low level switch indicates that the cartridge is empty and must be replaced.
For controller models (Option G), this activation will sound a buzzer, will illuminate the yellow Led on the front panel, will energise the fault
contact and will display EELL on the controller.
For terminal strip models (Option F), the low level switch should be wired into the controls of the host machine in order to inform the user
that the cartridge is empty and needs replacing.
Type A
1. Unscrew the gun barrel assembly from the CLP.
2. Retract rod fully.
3. Withdraw empty cartridge and discard carefully.
4. Carry out the steps outlined in “Loading a Cartridge” for Type A.
5. For Controller models, the “R” button must be pressed to resume CLP operation.
Type B
1. Unscrew the cartridge from the CLP.
2. Discard empty cartridge carefully.
3. Carry out the steps outlined in “Loading a Cartridge” for Type B
4. For Controller models, the “R” button must be pressed to resume CLP operation.
Type C
1. Unscrew the cartridge from the CLP.
2. Discard empty cartridge carefully.
3. Carry out the steps outlined in “Loading a Cartridge” for Type C
4. For Controller models, the “R” button must be pressed to resume CLP operation.
ATTENTION:
+
This sequence of steps is of
paramount importance.