11
2. How to measure
CAUTION
For the display unit purchased as a part of the Dyna Force set, set up procedure is already completed on delivery.
For the display unit purchased alone or to be used as a replacement, set up of the display unit is
required, as rated capacity and output vary depending on measuring unit. Refer to "3. How to set up
display unit" and follow the instructions. Neglecting to do so may lead to incorrect measurement.
Install a pullstud suitable for the machine to measure in the measuring device.
For machining centers with MAS or JIS standard spindles, your existing pullstud can be used.
However, for other standards such as DIN, ISO, CAT or ANSI, the pullstud exclusively designed for
Dyna Force is required.
Connect the measuring device to the display unit through an
exclusive cable. Ensure power of the display unit is turned off.
2-1 Installation of pullstud
2-2 Connection between measuring device and display unit
2-3 Power activation
2-4 Zero reset
CAUTION
●
Do not use
【
STRAIN
】
mode, as it is for error diagnosis by manufacturer.
If operated in
【
STRAIN
】
mode, resetting is required as indicated in
"3. How to set up display unit".
●
If the battery symbol is blinking, the battery charge is low. Replace the battery.
Measured values may vary due to slight difference in length of each
pullstud. If more stable measurement is required, always use the same
piece of pullstud.
If a pullstud is tightened too much, excessive load is applied to the
measuring element. Hand-tightened installation is recommended.
●
●
Display side (large)
Measuring device
side (small)
CAUTION
●
Be sure to connect the measuring
unit through an exclusive cable
before turning on the display unit.
• Push the
【
POWER
】
switch to turn on the power.
POWER
STRAIN
MEAS
POWER
STRAIN
MEAS
• The start-up screen is displayed for about 2 seconds,
then shifts to the measurement screen.
• Push the
【
POWER
】
switch again to turn on the backlight. Push the
【
POWER
】
switch again to turn off the backlight.
• Slide the power switch to the
【
MEAS
】
position and release it.
CAUTION
0.0
kN
ZERO
Push ZERO .
"ZERO" is displayed on the LCD and the displayed value changes to "0".
●
Make sure that "ZERO" is displayed on the LCD,
and proceed to the next page.
Содержание DynaForce
Страница 3: ...1 1 ZERO 2 1 1 2 3 4 5 6 7 STRAIN POWER STRAIN MEAS POWER STRAIN MEAS Ser No 1 2 5 7 3 4 TYPE DFA 1 6...
Страница 5: ...kN 10kN 1020kgf oL oL Ad Ad 3 2 MEAS STRAIN HOLD 2 OFF 3 2 POWER...
Страница 10: ...F 13 ENGLISH 4 1 F 14 3 4 F 14 11 F 11 TEDS F 12 4 1 3 F 15 4 1 F 10 4 1 EA...
Страница 11: ...ATC 0 60 5 40 20 85 RH OFF 2 1 BIG...
Страница 21: ...MEMO...
Страница 22: ...MEMO...
Страница 23: ...MEMO...
Страница 24: ...No 0619 3 3 39 TEL 072 982 2312 FAX 072 980 2231 www big daishowa co jp 579 8013...