8 |
P a g e
tes t
5-10 SECONDS IS REQUIRED TO ALLOW THE DC FAN TO RESPOND TO THE REMOTE EACH SPEED OR FAN
DIRECTION SELECTIONS, AS DC FANS INCORPORATE A SENSOR CONTROL W HICH CONTROLS THE POWER
TO THE MOTOR.
○
2 -
FAN OFF BUTTON:
Press the button to turn the fan off.
○
3 -
REVERSE FUNCTION BUTTON:
Press the button to activate the reverse running function. The fan must be operating to activate the reverse function.
THE RECEIVER PROVIDES THE FOLLOWING LEVEL OF PROTECTION AGAINST:
Lock position: the receiver has a built in safety feature to protect against obstruction during operation. The motor
will be locked from operation and will disconnect from power after 30 seconds of interruption. Please remove
obstacles before re-starting. To reset, simply turn off the power supply to the fan motor and re-start.
Over 80W protection: When the receiver detects power consumption which is greater than 80W, the receiver
power will be stopped and operation will immediately discontinue. Turn the receiver power on after 5 seconds to
restart the fan.
REPAIRING THE FAN RECEIVER & REMOTE PAIRING
Should the remote and receiver lose control after installation or during use, the pairing of the remote and the receiver
must be repaired. Below are the operating symptoms and method to repair the pairing of the DC ceiling fan remote and
receiver.
Issues:
Loss of control - Fan is only running at high speed after installation
Loss of control - No reverse function after installation
Loss of control - Remote cannot communicate with the receiver
Solution:
If the fan runs at the highest speed continuously, it means the wiring of the installation is correct. When the fan operates
on high speed only, or fails to operate in reverse function or any other command/s, it is recommended to repair the
communication pairing of the remote and receiver. Please follow the steps below:
A. Remove the battery cover on the remote. Make sure the battery is installed correctly and the red LED light
indicator will be flashing. This means the remote function is okay.