Installation, Operation and Maintenance Manual
September 2019
MAN720_IMVS2000v2_IOM Rev. 6
Section 4: Device Description
Device Description
Stroking Time Limits (***)
Min. Actuator Stroking Time
2 sec.
Max. Actutor Stroking Time
300 sec.
Max. Ratio between Op. and Cl. times
10 (****)
Modbus Rtu (optional card) (*****)
Transmission Technology
RS485
Baud rate (configurable)
600,1200,2400,4800,9600,19200,38400 bps
Parity Bit (configurable)
Even, Odd, None
Stop Bit (according to Parity Bit)
1, 2
Galvanic Insulation from Logic
Yes
4-20 mA Analog HART (optional card) (******)
Feedback Signal
Pressure or Position
Output Current Range
4-20 mA
Maximum Load (cable+resistor)
300 ohm
External Power Supply Voltage
21.6 - 26.4Vdc – max 21 mA
Galvanic Insulation from Logic
Yes
Notes:
(*)
Consult Factory for availability.
(**)
Consult Factory for applications over 345 barg.
(***)
Contact Biffi for the availability of applications that do not respect these ranges.
(****)
Ratio greater than 5 affects the accuracy of the PST.
(particularly for pneumatic application)
(*****)
See [3] for details.
(******)
See [2] for details.
(#)
For CSA/CSAus devices must be supplied from a limited energy source.
(voltage available is to be limited to 35 Vdc)
13
Содержание IMVS2000v2
Страница 2: ......