III Shortlist of Recommended Running and Starting Capacitors
Selected running capacitors for single-phase motors depending on the motor
design
Motor output (/kW)
0.55
0.75
1.1
Pole number
2
2
2
Rated voltage (/V)
230
115
230
115
230
115
Frequency (/Hz)
50
60
50
60
50
60
50
60
50
60
50
60
Running capacitor
(/µF)
20
20
80
80
25
25
100
100
31,5
31,5
125
125
Motor output (/kW)
1,3
1,5
2,2
Pole number
2
2
2
Rated voltage (/V)
230
115
230
115
230
115
Frequency (/Hz)
50
60
50
60
50
60
50
60
50
60
50
60
Running capacitor
(/µF)
36
36
125
125
36
36
140
140
55
55
220
220
Motor output (/kW)
0.55
0.75
1.1
Pole number
4
4
4
Rated voltage (/V)
230
115
230
115
230
115
Frequency (/Hz)
50
60
50
60
50
60
50
60
50
60
50
60
Running capacitor
(/µF)
20
20
80
80
25
25
100
100
31,5
31,5
125
125
Motor output (/kW)
1.3
1.5
2.2
Pole number
4
4
4
Rated voltage (/V)
230
115
230
115
230
115
Frequency (/Hz)
50
60
50
60
50
60
50
60
50
60
50
60
Running capacitor
(/µF)
40
40
160
160
45
45
160
160
65
65
260
260