9
RECEIVE UNIT SET-UP & TESTING:
WARNING
See “Product Safety Information”, page 4.
See “Inspection & Maintenance”, page 4.
1.
Place the Field Unit in a location where there is a clear view of the sky
(dashboard of automobile is suitable).
2.
Turn switch to the ON position, both lights (Red Power and White 1PPS
Data) should blink momentarily and then the red light (Power) should
remain on. If the red light continues to blink or does not stay on, batteries
are low and you will need to either plug it in to use or plug it in to charge
before use.
3.
Within several minutes the white light (1PPS Data) should begin blinking at
1 pulse per second. This will indicate a clear satellite signal is synced.
4.
Using a cellular phone, connect to the unit with either an audio cable or
through your phones Bluetooth. In order to link via a Bluetooth connection,
ensure your phone has its Bluetooth turned on. From the dropdown menu
of available devices, you will connect to one called pr1datalink. Access code
is 7425.
5.
Once connected, switch your audio to speaker mode and dial your base unit
number. After a few rings (number of rings vary depending on phone
systems) the auto-answer device should pick up and you should begin to
hear and audible set of tones sounding like a fax machine tone.
6.
Once a tone is received, switch to either headphone, or to your Bluetooth
connection. Once the connection is made, turn your Bluetooth volume all
the way up and the blinking white light should become solid with a slight
dimming pulse.
7.
If not completed already, return to the Send unit set-up procedure from
here to complete its set-up. If this has already been done, continue to the
next step
8.
If a “Degree Offset” is necessary in the field, i.e. Transmission to Distribution
readings (30 degree offset), working in another utility system (storm
damage, new construction), then the binary dip switches can be
manipulated anywhere from 0-360 degrees in the same manner as setting
up the Send Unit. See step 10 of the send unit set-up for instructions.
WARNING
Unit shall be tested before and after each use on a known voltage source.
Failure to do so could result in false negative indications.
Содержание Phasing Ranger 2
Страница 16: ...16 ...