8
SEND UNIT SET-UP & TESTING:
1.
Permanently place satellite receiver (GPS) where there is a clear view of the
sky, i.e. a window sill (non-tinted), preferably outside on the building
structure with a minimum distance of 16 inches from the wall.
2.
Attach Auto Answer Device to Send Unit labeled “TO AUTO ANSWER
DEVICE” via audio cable then attach Auto Answer Device to a
telephone
outlet.
3.
Plug in wall adapter into any 115 VAC standard outlet and plug other end
into Send Unit labeled “AC IN 15V MAX”. It is
Very
important that this
adapter is not
removed or rotated from this outlet, this is your Reference
Phase information. If the unit is ever moved or you notice your
measurements have shifted, repeat his procedure to align your base unit
again.
4.
Turn switch to the ON position, both lights will alternatingly blink between
red and white and then the red light (Power) should remain on. The white
may remain on for a few seconds but then go out again.
5.
Within several minutes the white light (1PPS Data) should go solid.
6.
The Send Unit is now ready to receive calls.
7.
Now set-up the Receive Unit before continuing to step 8.
8.
Turn on the Meter Probe (PD800W) and turn to the “DEG” position ONLY.
9.
Make Direct
contact with a known phase, i.e. “A, B or C” phase, “1, 2, or 3”
phase.
10.
If a 120-degree reading is expected while making direct contact but the
Meter Probe displays something different, you will need to adjust the
“Degrees Offset” binary switches (All defaulted UP) by switching down the
degrees to subtract from your current reading. For example, if you expected
120 but got 200, you would switch down the 64 and 16 switches. If you
expected 120 but got 90, you would switch down the 256, 64, 8, and 2.
Some small adjustments may have to be made till you get the desired
reading. Now your base unit is set-up to phase.
Содержание Phasing Ranger 2
Страница 16: ...16 ...