EN
L-L 261.00-BM
9 / 25
4.2.
POWER CONNECTIONS
Warning
The 220V equipment is fitted with a temporary power
cable, used for the final control test at factory. The
temporary power cord must be removed and replaced with
a proper power cord whose type and dimension shall be in
accordance with national rules.
Warning
The power line of the generator must feature an earthlead
and a residual current circuit breaker.
The supply cable must be connected to a switchboard
with sectioning switch.
Warning
When installed, the appliance must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70, and/or the CSA C22.1, Canadian Electrical
Code, if an external electrical source is utilized.
The electrical power cable must be connected in conformity to the
polarity specified on the main terminal board of the electrical panel:
phase (L) and neutral (N).
Warning
If polarities L and N are incorrect, the space heater may
stop a few seconds after it is switched on for the first
time.
Before switching on the heater and, therefore, before plugging it into
the electrical power supply, check that the power supply
specifications are the same as those stated on the identification
plate.
Any room thermostat or other accessories (such as a timer) are
connected to the system by connecting the electrical cable to the
thermostat plug (c):
• Take the plug (c) out of the electrical panel, open the plug and
remove the jumper between terminals 2 and 3.
• Connect the thermostat electrical cable to terminals 2 and 3 of the
thermostat plug (c).
• Close the plug again and plug it back into the panel.
Warning
Never attempt to switch the heater on or off by connecting
the room thermostat (or other control devices) to the
electrical power line.
The installation and connection of all the other accessories are
described in the specific instructions included with each accessory,
together with operating instructions.
The electrical diagram shown in this manual refers to the electrical
connection only.
4.3. CONNECTION TO HOT AIR DUCTS
4.3.1. AIR DELIVERY DUCTS
The space heater is set to operate with direct distribution of air.
Nevertheless, it can be connected to appropriately sized air
distribution channels, if required, with maximum diameter and
length as shown in the “TECHNICAL SPECIFICATION TABLE.”
Warning
Before starting the heater, check that the direction of
rotation of the fan matches the direction shown on the fan
itself.
The air distribution channels can be connected by using the various
accessories supplied, placing the connector head-on to one or more
outlets chosen as needed.
4.3.2. AIR SUCTION DUCTS
The heater can be connected to suction ducts to distribute air from
the room to be heated. These ducts must comply with the maximum
diameter and length specified in the “TECHNICAL SPECIFICATION
TABLE” and must be connected with accessory (A1) (provided), to
be assembled on the centrifugal fan casing.
The centrifugal fan has a panel (B1) with a sliding shutter (C1) to
emit fresh air for ventilation. The shutter can be set from a minimum
value (position D1) to a maximum value (position E1).
Warning
Accessory (A1) for connecting the air suction duct and
panel (B1) with pair flow adjustment shutter (C1) can be
assembled on either the right or left side of the fan casing.
NO
A1
B1
C1
D1
E1
Содержание TITAN 1000
Страница 20: ...L L 261 00 BM 20 25 ASSEMBLY INSTRUCTION NOTICE DE MONTAGE ...
Страница 21: ...L L 261 00 BM 21 25 FOOT HANDLE ASSEMBLY INSTRUCTION NOTICE DE MONTAGE DU PIED DE LA POIGNEE Mod 750 kBTU h ...
Страница 22: ...L L 261 00 BM 22 25 FOOT HANDLE ASSEMBLY INSTRUCTION NOTICE DE MONTAGE DU PIED DE LA POIGNEE Mod 750 kBTU h ...
Страница 23: ...L L 261 00 BM 23 25 FOOT HANDLE ASSEMBLY INSTRUCTION NOTICE DE MONTAGE DU PIED DE LA POIGNEE Mod 1 000 kBTU h ...
Страница 24: ...L L 261 00 BM 24 25 FOOT HANDLE ASSEMBLY INSTRUCTION NOTICE DE MONTAGE DU PIED DE LA POIGNEE Mod 1 000 kBTU h ...